Related Experiment Video
Updated: Feb 13, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
CT-derived left ventricular global strain in aortic valve stenosis patients: A comparative analysis pre and post
Introduction:
We assessed the potential of CT strain to detect changes in myocardial function in patients referred for TAVI pre and post intervention.
Patients And Methods:
25 consecutive patients with symptomatic aortic valve stenosis in whom TAVI had been performed were included in this analysis. Functional CT data sets acquired before and 3 to 6 months after TAVI were available. Multiphase reconstructions in increments of 10% of the cardiac cycle were rendered and transferred to a dedicated workstation (Ziostation2, Ziosoft Inc., Tokyo, Japan). For quantification of left ventricular strain, multiplanar reconstructions of the left ventricle in standard 4 chamber, 2 chamber as well as apical 3 chamber views were rendered. The perimeter of the left ventricle was traced dynamically through the cardiac cycle. Peak strain was calculated for each patient pre and post intervention. Furthermore, for quantification of 3-dimensional maximum principal strain, 2 volumetric regions of interests (VOI) were placed per each basal, mid and apical segment of the previously mentioned MPRs and peak maximal principal strain was calculated. Maximum principal strain as well as perimeter-derived longitudinal strain values in the three standard windows were averaged to obtain global strain.
Results:
25 patients were included in this analysis (mean age 78 ± 9 years, 13 males). Peak global maximum principal strain was significantly higher at follow-up compared to baseline (0.46 ± 0.19 vs. 0.59 ± 0.18, respectively, p = 0.001). Similarly global longitudinal strain derived by perimeter was significantly lower - implying better contraction - compared to baseline (-8.6% ± 2.8% vs. -9.8% ± 2.6%, respectively, p = 0.006).
Conclusion:
Using dedicated software, assessment of CT derived left ventricular strain is feasible. In patients treated with transcatheter aortic valve replacement, CT-derived parameters of global myocardial strain improve onshort-term follow-up.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Aortic Regurgitation IV: Nursing Management