Related Experiment Video
Updated: Feb 13, 2026

Endoscopic Endonasal Trans-sphenoidal Approach: Minimally Invasive Surgery for Pituitary Adenomas
Published on: January 17, 2018
Preoperative Computed Tomography (CT) Evaluation of Anatomical Abnormalities in Endonasal Transsphenoidal Approach in
Zhengyi Guo1, Chunli Liu1, Haifeng Hou2
1Taian City Central Hospital, Taian, Shandong, China (mainland).
Abstract:
BACKGROUND This study aimed to retrospectively analyze patient clinical data to investigate the effects of computed tomography (CT) reconstruction and the measurement of abnormal structures in the endonasal sphenoidal sinus approach on the operative effects in patients undergoing pituitary adenoma resection. MATERIAL AND METHODS The records of 53 patients who underwent pituitary adenoma resection via the endonasal transsphenoidal approach in the Neurosurgery Department of Tai'an City Central Hospital from December 2010 to June 2016 were analyzed retrospectively. All cases showed anatomical abnormalities in the endonasal transsphenoidal approach that were detected by conventional CT scans. The clinical data of the patients were reviewed. After review, 26 patients who underwent preoperative CT reconstruction and measurement of abnormal structures before surgery were included in the observation group (CT reconstruction group), and 27 patients who did not undergo CT reconstruction and measurement of abnormal structures were included in the control group. Data on intraoperative blood loss, surgical time, hospital stay, and postoperative complications were collected to assess the quality of the surgery. RESULTS Compared with the control group, the observation group showed less blood loss (p<0.001), a shorter operation time (p<0.001), fewer postoperative complications (p<0.001), and a shorter hospital stay (p<0.001). CONCLUSIONS Preoperative CT reconstruction and measurement of abnormal structures in patients undergoing pituitary adenoma resection by the endonasal transsphenoidal approach can improve operative quality and reduce complications.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Hypothalamic-Pituitary Axis
Imaging Studies III: Computed Tomography
Abnormal Proliferation
Hormones of the Pituitary Gland
The most abundantly secreted hormone from the anterior lobe is the growth hormone, which controls overall growth by...
The Pituitary Gland

