An In Vivo Blood-brain Barrier Permeability Assay in Mice Using Fluorescently Labeled Tracers
Published on: February 26, 2018
Non-contrast MR imaging of blood-brain barrier permeability to water
Zixuan Lin1, Yang Li2,3, Pan Su2,3
1Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland.
Purpose:
Many brain diseases are associated with an alteration in blood-brain barrier (BBB) and its permeability. Current methods using contrast agent are primarily sensitive to major leakage of BBB to macromolecules, but may not detect subtle changes in BBB permeability. The present study aims to develop a novel non-contrast MRI technique for the assessment of BBB permeability to water.
Methods:
The central principle is that by measuring arterially labeled blood spins that are drained into cerebral veins, water extraction fraction (E) and permeability-surface-area product (PS) of BBB can be determined. Four studies were performed. We first demonstrated the proof-of-principle using conventional ASL with very long post-labeling delays (PLD). Next, a new sequence, dubbed water-extraction-with-phase-contrast-arterial-spin-tagging (WEPCAST), and its Look-Locker (LL) version were developed. Finally, we demonstrated that the sensitivity of the technique can be significantly enhanced by acquiring the data under mild hypercapnia.
Results:
By combining a strong background suppression with long PLDs (2500-4500 ms), ASL spins were reliably detected in the superior sagittal sinus (SSS), demonstrating the feasibility of measuring this signal. The WEPCAST sequence eliminated partial voluming effects of tissue perfusion and allowed quantitative estimation of E = 95.5 ± 1.1% and PS = 188.9 ± 13.4 mL/100 g/min, which were in good agreement with literature reports. LL-WEPCAST sequence shortened the scan time from 19 min to 5 min while providing results consistent with multiple single-PLD acquisitions. Mild hypercapnia increased SNR by 78 ± 25% without causing a discomfort in participants.
Conclusion:
A new non-contrast technique for the assessment of global BBB permeability was developed, which may have important clinical applications.
More Related Videos
Related Concept Videos
The Blood-brain Barrier
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Permeability of Concrete
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Physiological Barriers
The blood endothelial barrier is the most porous of these. It allows all small ionized, un-ionized, and lipophilic molecules to pass through the endothelial lining into the interstitial space...