Cervical dilatation over time is a poor predictor of severe adverse birth outcomes: a diagnostic accuracy study
J P Souza1, O T Oladapo1, B Fawole2
1UNDP/UNFPA/ UNICEF/WHO/World Bank Special Programme of Research Development and Research Training in Human Reproduction (HRP), Department of Reproductive Health and Research, World Health Organization, Geneva, Switzerland.
Objective:
To assess the accuracy of the World Health Organization (WHO) partograph alert line and other candidate predictors in the identification of women at risk of developing severe adverse birth outcomes.
Design:
A facility-based, multicentre, prospective cohort study.
Setting:
Thirteen maternity hospitals located in Nigeria and Uganda.
Population:
A total of 9995 women with spontaneous onset of labour presenting at cervical dilatation of ≤6 cm or undergoing induction of labour.
Methods:
Research assistants collected data on sociodemographic, anthropometric, obstetric, and medical characteristics of study participants at hospital admission, multiple assessments during labour, and interventions during labour and childbirth. The alert line and action line, intrapartum monitoring parameters, and customised labour curves were assessed using sensitivity, specificity, positive and negative likelihood ratios, diagnostic odds ratio, and the J statistic.
Outcomes:
Severe adverse birth outcomes.
Results:
The rate of severe adverse birth outcomes was 2.2% (223 women with severe adverse birth outcomes), the rate of augmentation of labour was 35.1% (3506 women), and the caesarean section rate was 13.2% (1323 women). Forty-nine percent of women in labour crossed the alert line (4163/8489). All reference labour curves had a diagnostic odds ratio ranging from 1.29 to 1.60. The J statistic was less than 10% for all reference curves.
Conclusions:
Our findings suggest that labour is an extremely variable phenomenon, and the assessment of cervical dilatation over time is a poor predictor of severe adverse birth outcomes. The validity of a partograph alert line based on the 'one-centimetre per hour' rule should be re-evaluated.
Funding:
Bill & Melinda Gates Foundation, United States Agency for International Development (USAID), UNDP/UNFPA/UNICEF/WHO/World Bank Special Programme of Research, Development and Research Training in Human Reproduction (HRP), and WHO (A65879).
Tweetable Abstract:
The alert line in check: results from a WHO study.
Related Concept Videos
Birth Control Methods
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
Improving Translational Accuracy
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Acute Pyelonephritis II: Diagnostic Studies and Management
Uncertainty in Measurement: Accuracy and Precision