Related Experiment Video
Updated: Feb 13, 2026

High Precision Zinc Isotopic Measurements Applied to Mouse Organs
Published on: May 22, 2015
New methods for measuring atmospheric heavy noble gas isotope and elemental ratios in ice core samples
Bernhard Bereiter1,2,3, Kenji Kawamura4,5,6, Jeffrey P Severinghaus1
1Scripps Institution of Oceanography, University of California San Diego, La Jolla, CA, 92037, USA.
Rationale:
The global ocean constitutes the largest heat buffer in the global climate system, but little is known about its past changes. The isotopic and elemental ratios of heavy noble gases (krypton and xenon), together with argon and nitrogen in trapped air from ice cores, can be used to reconstruct past mean ocean temperatures (MOTs). Here we introduce two successively developed methods to measure these parameters with a sufficient precision to provide new constraints on past changes in MOT.
Methods:
The air from an 800-g ice sample - containing roughly 80 mL STP air - is extracted and processed to be analyzed on two independent dual-inlet isotope ratio mass spectrometers. The primary isotope ratios (δ15 N, δ40 Ar and δ86 Kr values) are obtained with precisions in the range of 1 per meg (0.001‰) per mass unit. The three elemental ratio values δKr/N2 , δXe/N2 and δXe/Kr are obtained using sequential (non-simultaneous) peak-jumping, reaching precisions in the range of 0.1-0.3‰.
Results:
The latest version of the method achieves a 30% to 50% better precision on the elemental ratios and a twofold better sample throughput than the previous one. The method development uncovered an unexpected source of artefactual gas fractionation in a closed system that is caused by adiabatic cooling and warming of gases (termed adiabatic fractionation) - a potential source of measurement artifacts in other methods.
Conclusions:
The precisions of the three elemental ratios δKr/N2 , δXe/N2 and δXe/Kr - which all contain the same MOT information - suggest smaller uncertainties for reconstructed MOTs (±0.3-0.1°C) than previous studies have attained. Due to different sensitivities of the noble gases to changes in MOT, δXe/N2 provides the best constraints on the MOT under the given precisions followed by δXe/Kr, and δKr/N2 ; however, using all of them helps to detect methodological artifacts and issues with ice quality.
More Related Videos
Related Concept Videos
Elements: Chemical Symbols and Isotopes
Some symbols are derived from the common English name of the element; others are abbreviations of the name in another language — Latin, Greek or German. For example, the symbol for aluminum (common name)...
Noble Gases
The elements in group 18 are noble gases (helium, neon, argon, krypton, xenon, and radon). They earned the name “noble” because they were assumed to be nonreactive since they have filled valence shells. In 1962, Dr. Neil Bartlett at the University of British Columbia proved this assumption to be false.
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Isotopes
An element's atomic mass, or weight,...
Periodic Classification of the Elements
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....