A randomized study of four different types of tympanostomy ventilation tubes - Full-term follow-up
Johan Knutsson1, Claudia Priwin2, Anne-Charlotte Hessén-Söderman3
1Dept of Otorhinolaryngology, Västmanland County Hospital, Sweden; Centre for Clinical Research, Uppsala University, Västmanland County Hospital, Västerås, Sweden; Dept of Otolaryngology, Örebro University Hospital, Sweden.
Objective:
To evaluate the impact of tympanostomy ventilation tube material (silicone vs fluoroplastic) and shape (short vs long) regarding time to extrusion, occurrence of otorrhea, occlusion, tube removal and occurrence of persistent perforation.
Methods And Material:
Four different types of ventilation tubes were used; Long Armstrong tubes, Donaldson tubes, Shepard tubes and straight tubes, representing four specific combinations of VT material (silicone or fluoroplastic) and shape (short, double flanged or long, single flanged). Four hundred children scheduled for bilateral tube insertion were included in a randomized trial. The patients received one type of tube in the right ear and another type in the left ear. The incidence of tube extrusion and complications were monitored postoperatively every third month by an otolaryngologist.
Results:
Twenty-two children were excluded during surgery. Out of the studied 378 children the mean age was 35.3 months. 63.8% were boys. Short tubes extruded earlier than long tubes; hazard ratio (HR) 4.84 (95% CI 3.50-6.69, p < 0.001). Long Armstrong tubes were least prone to extrude. Silicone tubes resulted in significantly longer time to first infection in a VT ear, HR 1.68 (95% CI 1.03-2.76, p = 0.039). Donaldson tubes rendered the longest mean time to first infection (p = 0.025). Infections did not affect tube extrusion rates significantly (p = 0.879). No significant differences were found regarding tube occlusion, tube extraction or persistent perforation.
Conclusions:
Long tubes are less prone to extrude early. Long Armstrong tubes have the least propensity to extrude early. Silicone tubes render significantly longer time to first infection. Donaldson tubes result in least infections. Infection does not affect extrusion rates significantly.
Level Of Evidence:
1b.
More Related Videos
07:39Longitudinal Follow-Up of Urinary Tract Infections and Their Treatment in Mice using Bioluminescence Imaging
Published on: June 14, 2021
09:52Modified Roller Tube Method for Precisely Localized and Repetitive Intermittent Imaging During Long-term Culture of Brain Slices in an Enclosed System
Published on: December 28, 2017
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Randomized Experiments
Simple randomization
Simple...