Related Experiment Video
Updated: Feb 13, 2026

Implantation of Inferior Vena Cava Interposition Graft in Mouse Model
Published on: June 4, 2014
Development of a postoperative occlusive thrombus at the site of an implanted inferior vena cava filter: A case
Ayako Kukida1, Yasushi Takasaki, Mio Nakata
1Department of Anesthesia and Perioperative Medicine Department of Gastrointestinal Surgery and Surgical Oncology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
Rationale:
Although an inferior vena cave (IVC) filter is placed to prevent fatal pulmonary embolism (PE), several complications associated with an IVC filter have been reported. We describe a case with symptomatic PE, of which the origin was an occlusive IVC thrombus that developed from the placement of an IVC filer after a laparoscopy-assisted total gastrectomy (LATG).
Patient Concerns:
A 71-year-old man underwent LATG under general anesthesia alone. He had an IVC filter implanted 13 years ago. An intravenous infusion of unfractionated heparin was substituted for the discontinuation of oral warfarin four days before the surgery. The proposed operation was performed and took a total of 404 minutes including the total duration of pneumoperitoneum that took 374 minutes. After the surgery, he experienced severe shivering reactions that required frequent bolus infusions of antihypertensive drugs. On the third postoperative day, he complained of dyspnea after taking a short walk, and subsequently lost consciousness. While he spontaneously recovered without requiring any resuscitation efforts, we performed computed tomography (CT) examination for suspected PE.
Diagnoses:
The CT showed that a massive thrombus was occupying the intravenous space from the IVC filter to the left common iliac vein with several embolic defects in the peripheral pulmonary arteries present.
Interventions:
An anticoagulant therapy was established with 10 mg of oral apixaban given twice a day for the first four days, followed by a reduction to 5 mg.
Outcomes:
On the 17th postoperative day, an ultrasound vascular examination confirmed the complete disappearance of deep venous thrombus (DVT).
Lessons:
As an IVC filter itself may be a potential source of DVT, we should carefully manage patients with a previously implanted IVC filter throughout the perioperative period.
Related Concept Videos
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active Filters
Data Reporting and Recording
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Peripheral Artery Disease V: Postoperative Nursing Management
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...