Effects of Resolution, Range, and Image Contrast on Target Acquisition Performance
Related Experiment Video
Updated: Feb 13, 2026

Rapid Acquisition of 3D Images Using High-resolution Episcopic Microscopy
Published on: November 21, 2016
Justin G Hollands1, Phil Terhaar1, Nada J Pavlovic1
1Defence Research and Development Canada, Toronto.
Objective:
We sought to determine the joint influence of resolution, target range, and image contrast on the detection and identification of targets in simulated naturalistic scenes.
Background:
Resolution requirements for target acquisition have been developed based on threshold values obtained using imaging systems, when target range was fixed, and image characteristics were determined by the system. Subsequent work has examined the influence of factors like target range and image contrast on target acquisition.
Method:
We varied the resolution and contrast of static images in two experiments. Participants (soldiers) decided whether a human target was located in the scene (detection task) or whether a target was friendly or hostile (identification task). Target range was also varied (50-400 m). In Experiment 1, 30 participants saw color images with a single target exemplar. In Experiment 2, another 30 participants saw monochrome images containing different target exemplars.
Results:
The effects of target range and image contrast were qualitatively different above and below 6 pixels per meter of target for both tasks in both experiments.
Conclusion:
Target detection and identification performance were a joint function of image resolution, range, and contrast for both color and monochrome images.
Application:
The beneficial effects of increasing resolution for target acquisition performance are greater for closer (larger) targets.
Related Concept Videos
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Light Acquisition
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...
Variation: Normal Distribution, Range, and Standard Deviation

