Related Experiment Video
Updated: Feb 13, 2026

Isolation Method for Long-Term and Short-Term Hematopoietic Stem Cells
Published on: May 19, 2023
Short-term nighttime wind turbine noise and cardiovascular events: A nationwide case-crossover study from Denmark
Aslak Harbo Poulsen1, Ole Raaschou-Nielsen2, Alfredo Peña3
1Diet, Genes and Environment, Danish Cancer Society Research Center, Copenhagen, Denmark.
Aims:
The number of people exposed to wind turbine noise (WTN) is increasing. WTN is reported as more annoying than traffic noise at similar levels. Long-term exposure to traffic noise has consistently been associated with cardiovascular disease, whereas effects of short-term exposure are much less investigated due to little day-to-day variation of e.g. road traffic noise. WTN varies considerably due to changing weather conditions allowing investigation of short-term effects of WTN on cardiovascular events.
Methods And Results:
We identified all hospitalisations and deaths from stroke (16,913 cases) and myocardial infarction (MI) (17,559 cases) among Danes exposed to WTN between 1982 and 2013. We applied a time-stratified, case-crossover design. Using detailed data on wind turbine type and hourly wind data at each wind turbine, we simulated mean nighttime outdoor (10-10,000 Hz) and nighttime low frequency (LF) indoor WTN (10-160 Hz) over the 4 days preceding diagnosis and reference days. For indoor LF WTN between 10 and 15 dB(A) and above 15 dB(A), odds ratios (ORs) for MI were 1.27 (95% confidence interval (CI): 0.97-1.67; cases = 198) and 1.62 (95% CI: 0.76-3.45; cases = 21), respectively, when compared to indoor LF WTN below 5 dB(A). For stroke, corresponding ORs were 1.17 (95% CI: 0.95-1.69; cases = 166) and 2.30 (95% CI: 0.96-5.50; cases = 15). The elevated ORs above 15 dB(A) persisted across sensitivity analyses. When looking at specific lag times, noise exposure one day before MI events and three days before stroke events were associated with the highest ORs. For outdoor WTN at night, we observed both increased and decreased risk estimates.
Conclusion:
This study did not provide conclusive evidence of an association between WTN and MI or stroke. It does however suggest that indoor LF WTN at night may trigger cardiovascular events, whereas these events seemed largely unaffected by nighttime outdoor WTN. These findings need reproduction, as they were based on few cases and may be due to chance.
Related Concept Videos
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Imaging Studies for Cardiovascular System V: CT
Turbine-Governor Control
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...

