Prospective Evaluation of a Low-Dose Radiation Fluoroscopy Protocol for Minimally Invasive Transforaminal Lumbar

Luis M Tumialán1,2, Justin C Clark1, Laura A Snyder1

  • 1Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona.

Abstract

Insights

A new low-dose radiation fluoroscopy protocol for minimally invasive surgery for transforaminal lumbar interbody fusion (MIS TLIF) significantly reduces radiation exposure and fluoroscopy time. This protocol maintains visualization and procedural safety, optimizing radiation dose and acquisition time.

Area of Science:

  • Neurosurgery
  • Orthopedic Surgery
  • Medical Imaging

Background:

  • Radiation exposure is a concern in minimally invasive surgery for transforaminal lumbar interbody fusion (MIS TLIF).
  • A low-dose radiation fluoroscopy protocol has been developed to reduce fluoroscopy times and radiation exposure.
  • Previous research indicated the potential benefits of this protocol.

Purpose of the Study:

  • To prospectively evaluate a previously reported low-dose radiation fluoroscopy protocol for MIS TLIF.
  • To assess the impact of the protocol on fluoroscopy time, radiation dose, and operative efficiency.

Main Methods:

  • Prospective evaluation of 65 consecutive patients undergoing MIS TLIF using a low-dose radiation fluoroscopy protocol.
  • Analysis of total fluoroscopy time, radiation dose, and operative times for all enrolled patients.
  • Placement of 260 pedicle screws was performed during the procedures.

Main Results:

  • The study included 65 patients (43 women, 22 men) with a mean age of 63 years.
  • Mean operative time was 178.7 minutes, mean fluoroscopic time was 10.43 seconds.
  • Mean radiation dose was 0.295 mGy × m2, with a range of 0.092-0.314 mGy × m2.

Conclusions:

  • The low-dose protocol, combining pulsed and digital spot images, reduces fluoroscopy time and radiation dose in MIS TLIF.
  • Visualization of bony anatomy, procedure safety, and efficiency were not compromised.
  • The protocol decouples fluoroscopy time from radiation dose, primarily due to digital spot imaging, emphasizing optimization of both dose and acquisition time.

Related Concept Videos

Biological Effects of Radiation02:59

Biological Effects of Radiation

All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
18.1K
Nuclear Fusion02:45

Nuclear Fusion

The process of converting very light nuclei into heavier nuclei is also accompanied by the conversion of mass into large amounts of energy, a process called fusion. The principal source of energy in the sun is a net fusion reaction in which four hydrogen nuclei fuse and ultimately produce one helium nucleus and two positrons.
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
33.9K
Radiation: Applications01:17

Radiation: Applications

The average temperature of Earth is the subject of much current discussion. Earth is in radiative contact with both the Sun and dark space; it receives almost all its energy from the radiation of the Sun and reflects some of it into outer space. Dark space is very cold, about 3 K, so Earth radiates energy into it. For instance, heat transfer occurs from soil and grasses, the rate of which can be so rapid that frost can occur on clear summer evenings, even in warm latitudes.
The average...
1.8K
Absorption of Radiation01:05

Absorption of Radiation

The rate of heat transfer by emitted radiation is described by the Stefan-Boltzmann law of radiation:
1.3K
Dose Size and Dosing Frequency: Determination Methods01:21

Dose Size and Dosing Frequency: Determination Methods

Determining the optimal dose size and dosing frequency in pharmacotherapy is crucial for achieving therapeutic effectiveness while minimizing adverse effects. This article explores the methodologies employed in determining these parameters, focusing on their significance and interplay to tailor dosing regimens.Dose Size: Dose size refers to the amount of a drug administered in a single dose. It is determined based on the drug's pharmacodynamics and pharmacokinetics properties and...
329
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses01:25

Determination of Multiple Dosing Parameters: Loading and Maintenance Doses

A loading dose is an essential pharmacological strategy to rapidly achieve the target plasma drug concentration necessary for an immediate therapeutic effect. This approach is especially critical for drugs characterized by slow absorption or extended half-lives, where delaying therapeutic plasma levels could compromise treatment outcomes. By administering a loading dose, clinicians ensure a prompt onset of drug action, even for agents with complex pharmacokinetic profiles.Achieving steady-state...
252