Related Experiment Video
Updated: Feb 13, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Transcatheter aortic valve implantation with a mechanically expandable prosthesis: a learning experience for
Jasmin Ortak1,2, Giuseppe D'Ancona3,4, Hüseyin Ince1,2
1Department of Cardiology, Vivantes Klinikum im Friedrichshain und Am Urban, Landsberger Allee 49, 10249, Berlin, Germany.
Background:
Permanent pacemaker implantation (PPMI) after transcatheter aortic valve implantation (TAVI) remains an issue open for criticism. Aim of this study is to investigate a strategy to reduce PPMI rate after TAVI in general and more specifically after implantation of the LOTUS® prosthesis.
Methods:
Through our learning curve, we have developed a structured protocol to reduce PPMI rate. The protocol includes: shallow implantation depth within the native annulus, strict adherence to the international guidelines for PPMI, PPMI not earlier than 5 days after TAVI, and intravenous chronotropic and steroidal treatment (orciprenaline 0.6-1.7 mg/h i.v. and dexamethasone 25 mg/day i.v. for a maximum of 5 days) in case of acute onset of intraventricular and/or atrio-ventricular conduction disturbances after TAVI.
Results:
The first 35 patients (group A) were managed as per routine in our early stage experience with the LOTUS valve. The PPMI reduction protocol was applied in the second phase on the last 31 patients (group B). The PPMI rate was reduced from 34.3% (12/35) to 9.7% (3/31) (p = 0.02). At logistic regression analysis being treated in the second phase of our experience (group B) had a protective effect against PPMI (p = 0.05; OR = 0.1; CI = 0.01-1.0). Prosthesis implantation depth was directly related to PPMI (p = 0.005; OR = 2.0; CI = 1.2-3.2). Receiver operating characteristic curve analysis confirmed that a LOTUS implantation depth > 4.8 mm was the cut-off to predict PPMI (AUC = 0.8; p = 0.003; CI = 0.6-0.9) with maximal sensitivity (78.6%) and specificity (73.2%).
Conclusions:
PPMI rate after LOTUS can be reduced with experience by applying specific clinical and operative strategies.
More Related Videos
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Benzene to 1,4-Cyclohexadiene: Birch Reduction Mechanism
Oxidation-Reduction Reactions
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Measuring Reaction Rates
Speciation Rates