Related Experiment Video
Updated: Feb 13, 2026

Workflow and Tools for Crystallographic Fragment Screening at the Helmholtz-Zentrum Berlin
Published on: March 3, 2021
Modelling resonant arrays of the Helmholtz type in the time domain
Agnès Maurel1, Jean-Jacques Marigo2, Jean-François Mercier3
1Institut Langevin, CNRS, ESPCI ParisTech, 1 rue Jussieu, 75005 Paris, France.
Abstract:
We present a model based on a two-scale asymptotic analysis for resonant arrays of the Helmholtz type, with resonators open at a single extremity (standard resonators) or open at both extremities (double-sided resonators). The effective behaviour of such arrays is that of a homogeneous anisotropic slab replacing the cavity region, associated with transmission, or jump, conditions for the acoustic pressure and for the normal velocity across the region of the necks. The coefficients entering in the effective wave equation are simply related to the fraction of air in the periodic cell of the array. Those entering in the jump conditions are related to near field effects in the vicinity of the necks and they encapsulate the effects of their geometry. The effective problem, which accounts for the coupling of the resonators with the surrounding air, is written in the time domain which allows us to question the equation of energy conservation. This is of practical importance if the numerical implementations of the effective problem in the time domain is sought.
Related Concept Videos
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Conservation of Protein Domains Over Different Proteins
A limited set of protein domains often duplicate and recombine during evolution. These domains can be organized in different combinations to...

