Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students
Published on: June 16, 2018
Development and feasibility of a wearable infant wrist band for the objective measurement of physical activity using
Alessandra Prioreschi1, Thomas Nappey2, Kate Westgate3
11MRC/WITS Developmental Pathways for Health Research Unit, Department of Paediatrics, School of Clinical Medicine, Faculty of Health Sciences, University of Witwatersrand, Johannesburg, South Africa.
Insights
A new wearable wristband accurately measures infant and toddler physical activity. Caregivers found the device feasible and acceptable for monitoring young children's movement.
Area of Science:
- Pediatrics
- Biomedical Engineering
- Public Health
Background:
- Reliable measurement of infant and toddler physical activity is crucial for assessing guideline adherence and understanding developmental impacts.
- Current methods may lack feasibility or accuracy for this age group.
- Developing accurate and user-friendly tools is essential for early life health research.
Purpose of the Study:
- To develop and evaluate a novel infant wearable wrist-worn band for physical activity measurement.
- To assess the feasibility of using data from the wearable band for observational physical activity measurement.
- To determine caregiver-reported acceptability of the infant wearable wrist band.
Main Methods:
- A final wearable band design was created to house an Axivity AX3 monitor.
- 152 mother-infant/toddler pairs (3-24 months) participated, with infants wearing the band for 1 week.
- Feasibility was assessed through data reliability, wear time compliance, and caregiver acceptability questionnaires.
Main Results:
- Technical reliability of the monitors was good, with 94% of participants providing sufficient valid data.
- Most mothers (60%) reported being "very happy" with the device's safety.
- Caregivers rated the band's comfort highly (80% "comfortable", 10% "very comfortable").
Conclusions:
- The developed infant wearable band is a feasible and acceptable tool for measuring physical activity in infants and toddlers.
- High compliance rates indicate the practicality of using this device in research.
- This provides a replicable, comfortable, and acceptable method for monitoring early childhood physical activity.
Background:
It is important to be able to reliably and feasibly measure infant and toddler physical activity in order to determine adherence to current physical activity guidelines and effects on early life development, growth and health. This study aimed to describe the development of an infant wearable wrist-worn band for the measurement of physical activity; to determine the feasibility of the device data for observational measurement of physical activity and to determine the caregiver reported acceptability of the infant wearable wrist band.
Methods:
After various iterations of prototypes and piloting thereof, a final wearable band was designed to fit an Axivity AX3 monitor. Mother and infant/toddler (aged 3-24 months) pairs (n = 152) were recruited, and mothers were asked for their child to wear the band with enclosed monitor at all times for 1 week (minimum 3 days). Feasibility was assessed by determining technical reliability of the data, as well as wear time and compliance according to requirements for observational measurement. Acceptability was assessed via questionnaire.
Results:
Technical reliability of the Axivity AX3 monitors in this age group was good. After excluding days that did not have at least 15 h of wear time, only 2% of participants had less than three valid days of data remaining, and 4% of participants had no data (due to device loss or data loss). Therefore, 94% of participants were compliant, having three or more days of wear with at least 15 h of wear per day, thus providing enough valid data for observational measurement. The majority (60%) of mothers reported being "very happy" with the safety of the device, while only 8% were "a little worried". A large majority (86%) of mothers stated that the band attracted attention from others, although this was mostly attributed to curiosity about the function of the band. Most (80%) of participants rated the comfort of the band as "comfortable", and 10% rated it as "very comfortable".
Conclusions:
The infant wearable band proved to be feasible and acceptable according to the criteria tested, and compliance wearing the band was good. We have therefore provided a replicable, comfortable and acceptable wearable band for the measurement of infant and toddler physical activity.
Related Concept Videos
Band Theory
The energy difference between these bands is known as the band gap.
Conductor, Semiconductor,...
Physical and Chemical Properties of Matter
Energy Bands in Solids
Band Formation:
When atoms are brought close together, as in a solid, these discrete energy levels begin to split due to the overlap of electron orbitals from adjacent atoms. This split occurs because of the Pauli exclusion principle, which states...
Velocity of an Object
Physical Pendulum
When dealing with complicated systems, the mass moment of inertia is an important parameter, as it...
Potential Due to a Polarized Object