Meta-Analysis of Time in Therapeutic Range in Continuous-Flow Left Ventricular Assist Device Patients Receiving
Brandon K Martinez1, Brenda Yik2, Raymond Tran2
1Hartford Hospital, Department of Pharmacy, Hartford, CT, USA.
Abstract:
Continuous-flow left ventricular assist devices (CF-LVADs) prolong survival in advanced heart failure patients. Anticoagulation control is critical in CF-LVAD patients due to increased thromboembolic and bleeding risk. We assessed the quality of INR control in CF-LVAD patients measured by time in therapeutic range (TTR). We performed a systematic literature search of MEDLINE and SCOPUS through July 2017 to identify studies evaluating TTR in anticoagulated adult CF-LVAD patients. Data on key characteristics and the TTR end point were then extracted from each study by two investigators using a standardized tool. Using a Hartung-Knapp random effects model, a weighted mean TTR estimate with accompanying 95% confidence interval (CI) was calculated. Statistical heterogeneity was estimated using the I2 statistic. Five published studies were included. All studies were single-center, retrospective investigations that calculated TTR using the Rosendaal method. Sample sizes ranged from 11 to 115 patients (total of 270 patients) with durations of follow-up ranging from 9 to 76 person-years. On meta-analysis, CF-LVAD patients had a weighted mean TTR of 46.6% (95% CI: 36.0-57.3%, I2 = 94%). This suggests that warfarin is difficult to manage in CF-LVAD patients, which may contribute to high rates of bleeding and thromboembolic complications.
Related Concept Videos
Continuous -time Fourier Transform
Basic Continuous Time Signals
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
Sampling Continuous Time Signal
In the...
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Receiver Operating Characteristic Plot