Related Experiment Video
Updated: Feb 13, 2026

Electrospray Deposition of Uniform Thickness Ge23Sb7S70 and As40S60 Chalcogenide Glass Films
Published on: August 19, 2016
Physical Properties, Film Thickness, and Bond Strengths of Resin-Modified Glass Ionomer Cements According to Their
Taiseer A Sulaiman1, Awab A Abdulmajeed1, Ali Altitinchi1
1Department of Operative Dentistry, University of North Carolina at Chapel Hill School of Dentistry, Chapel Hill, NC.
Purpose:
To determine the effect of changing the dispensing or mixing method of resin-modified glass ionomer (RMGI) cements on their water sorption, solubility, film thickness, and shear bond strength.
Materials And Methods:
Disc-shaped specimens of RMGI cements (RelyX: Luting [handmix], Luting Plus [clicker-handmix], Luting Plus [automix], GC: Fuji PLUS [capsule-automix], FujiCEM 2 [automix], [n = 10]) were prepared according to ISO standard 4049 for water sorption and solubility tests. Furthermore, the percentage of mass change, percentage of solubility, and percentage of water absorbed was also determined. Film thickness was measured according to ISO standard 9917-2; the mean of 5 measurements for each cement was calculated. Shear bond strength for each cement was determined according to ISO standard 29022 before and after thermocycling at 20,000 cycles, temperatures 5 to 55°C with a 15-second dwell time (n = 10/subgroup). Two- and one-way ANOVA were used to analyze data for statistical significance (p < 0.05).
Results:
Water sorptions of the RMGI cements were in close range (214-250 μg/mm3 ) with no statistical differences between counterparts (p > 0.05). RelyX Luting Plus (clicker-handmix) displayed lower solubility than its handmix and automix counterparts (p < 0.05). Film thickness of RelyX cements was significantly different (p < 0.05). RelyX Luting Plus (automix) had the lowest film thickness (19 μm) compared to its handmix (48 μm) and clicker-handmix (117 μm) counterparts (p < 0.05). GC Fuji PLUS (capsule-automix, 22 μm) was significantly lower than the automix version (GC FujiCEM 2, 127 μm) (p < 0.05). Shear bond strength of RelyX Luting Plus (automix) was significantly lower than its handmix and clicker-handmix versions (p < 0.05). GC Fuji PLUS (capsule-automix) was significantly higher than GC FujiCEM 2 (automix) (p < 0.05). The binary interaction of the two independent variables (dispensing/mixing method and thermocycling) was significant for the shear bond strengths of the GC cements only (p < 0.05).
Conclusions:
Change in the dispensing/mixing method of RMGI cement from the same brand may have an effect on its physical properties, in addition to its film thickness and shear bond strength. Newer, easier, and faster cement delivery systems are not necessarily better. Clinical outcomes of these differences are yet to be confirmed.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Physical and Chemical Properties of Matter
Bonding and Strength of Aggregate
Physical Properties of Amines
Physical Properties Affecting Solubility
As for any solution, the solubility of a gas in a liquid is affected by the attractive intermolecular forces between solute and solvent species. Unlike solid and liquid solutes, however, there is no solute-solute intermolecular attraction to overcome when a gaseous solute dissolves in a liquid solvent since the atoms or molecules comprising a gas are far separated and experience negligible interactions. Consequently, solute-solvent interactions are the sole...
Physical Properties of Alkanes