Wakefulness evaluation during sleep for healthy subjects and OSA patients using a patch-type device
Heenam Yoon1, Su Hwan Hwang1, Sang Ho Choi1
1Interdisciplinary Program in Bioengineering, Seoul National University, Seoul, South Korea.
Objectives:
Obstructive sleep apnea (OSA) is a major sleep disorder that causes insufficient sleep, which is linked with daytime fatigue and accidents. Long-term sleep monitoring can provide meaningful information for patients with OSA to prevent and manage their symptoms. Even though various methods have been proposed to objectively measure sleep in ambulatory environments, less reliable information was provided in comparison with standard polysomnography (PSG). Therefore, this paper proposes an algorithm for distinguishing wakefulness from sleep using a patch-type device, which is applicable for both healthy individuals and patients with OSA.
Methods:
Electrocardiogram (ECG) and 3-axis accelerometer signals were gathered from the single device. Wakefulness was determined with six parallel methods based on information about movement and autonomic nervous activity. The performance evaluation was conducted with five-fold cross validation using the data from 15 subjects with a low respiratory disturbance index (RDI) and 10 subjects with high RDI. In addition, wakefulness information, including total sleep time (TST), sleep efficiency (SE), sleep onset latency (SOL), and wake after sleep onset (WASO), were extracted from the proposed algorithm and compared with those from PSG.
Results:
According to epoch-by-epoch (30 s) analysis, the performance results of detecting wakefulness were an average Cohen's kappa of 0.60, accuracy of 91.24%, sensitivity of 64.12%, and specificity of 95.73%. Moreover, significant correlations were observed in TST, SE, SOL, and WASO between the proposed algorithm and PSG (p < 0.001).
Conclusions:
Wakefulness-related information was successfully provided using data from the patch-type device. In addition, the performance results of the proposed algorithm for wakefulness detection were competitive with those from previous studies. Therefore, the proposed system could be an appropriate solution for long-term objective sleep monitoring in both healthy individuals and patients with OSA.
More Related Videos
11:26Home-Based Transcranial Direct Current Stimulation Device Development: An Updated Protocol Used at Home in Healthy Subjects and Fibromyalgia Patients
Published on: July 14, 2018
04:33Author Spotlight: Unveiling the Connection Between Sleep Disorders and Cognitive Symptoms in Depression
Published on: April 26, 2024
Related Concept Videos
Bioavailability Study Design: Healthy Subjects Versus Patients
Sleep-Wake Cycles
NREM Sleep
NREM sleep comprises four progressive stages that seamlessly merge:
Types of Hormones
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Long-patch Base Excision Repair
Stages of Sleep
Before sleep begins, in wakefulness, the brain exhibits primarily beta waves, which are high in frequency and low in amplitude, indicating alertness...