Related Experiment Video
Updated: Feb 13, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Detection of multipoint pulse waves and dynamic 3D pulse shape of the radial artery based on binocular vision theory
Dongmei Lin1, Aihua Zhang1, Jason Gu2
1College of Electrical and Information Engineering, Lanzhou University of Technology, Lanzhou, China; Key Laboratory of Gansu Advanced Control for Industrial Processes, Lanzhou University of Technology, Lanzhou, China; National Experimental Teaching Center of Electrical and Control Engineering, Lanzhou University of Technology, Lanzhou, China.
Background And Objective:
Pulse signals contain a wealth of human physiological and pathological information. How to get full pulse information is especially challenging, and most of the traditional pulse sensors can only get the pulse wave of a single point. This study is aimed at developing a binocular pulse detection system and method to obtain multipoint pulse waves and dynamic three-dimensional pulse shape of the radial artery.
Methods:
The proposed pulse detection approach is image-based and implemented by two steps. First, a new binocular pulse detection system is developed based on the principle of pulse feeling used in traditional Chinese medicine. Second, pulse detection is achieved based on theories and methods of binocular vision and digital image processing. In detail, the sequences of pulse images collected by the designed system as experimental data are sequentially processed by median filtering, block binarization and inversion, area filtering, centroids extraction of connected regions, to extract the pattern centroids as feature points. Then stereo matching is realized by a proposed algorithm based on Gong-shape scan detection. After multipoint spatial coordinate calculation, dynamic three-dimensional reconstruction of the thin film shape is completed by linear interpolation. And then the three-dimensional pulse shape is achieved by finding an appropriate reference time. Meanwhile, extraction of multipoint pulse waves of the radial artery is accomplished by using a suitable reference origin. The proposed method is analyzed from three aspects, which are pulse amplitude, pulse rate and pulse shape, and compared with other detection methods.
Results:
Analysis of the results shows that the values of pulse amplitude and pulse rate are consistent with the characteristics of pulse wave of the radial artery, and pulse shape can correctly present the shape of pulse in space and its change trend in time. The comparison results with the other two previously proposed methods further verify the correctness of the presented method.
Conclusions:
The designed binocular pulse detection system and proposed algorithm can effectively detect pulse information. This tactile visualization-based pulse detection method has important scientific significance and broad application prospects and will promote further development of objective pulse diagnosis.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
VSEPR Theory and the Basic Shapes
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences