Related Experiment Video
Updated: Feb 13, 2026

Author Spotlight: Development of a Smartphone-Enhanced Paper-Based Device for Rapid Dengue NS1 Detection
Published on: January 26, 2024
A smartphone-based double-channel fluorescence setup for immunoassay of a carcinoembryonic antigen using CuS
Honghai Wang1, Yan Sun, Weiwei Yue
1College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of MoleCular and Nano Probes, Ministry of Education, Shandong Provincial Key Laboratory of Clean Production of Fine Chemicals, Shandong Normal University, Jinan 250014, P. R. China. kangqi@sdnu.edu.cn dzshen@sdnu.edu.cn.
Abstract:
Sensitive detection of cancer biomarkers is valuable for clinical diagnosis and treatment assessment of cancers. Herein, we report a simple smartphone-based double-channel fluorescence setup for immunoassay. Not including the smartphone, the total cost of the detection device itself is about 80 $, including a laser pointer, a twinning measurement cell, a collective lens, and an outside box. The fluorescence images of the sample and reference areas were captured by the camera in the smartphone and the brightness ratio was calculated using a user-edited smartphone app. By using 2,3-diaminophenazine (DAP) as the model luminophore, the influence of exposure time and photosensitivity on the sensitivity was tested. The brightness ratio offers high stability of the fluorescence signal, which is helpful to improve the sensitivity. The applicability of this device was demonstrated by a catalytic fluorimetric method for Cu2+ determination, which is based on the oxidation of o-phenylenediamine (non-fluorescent) to DAP (strong fluorescent) by dissolved oxygen using Cu2+ as the catalyst. Accordingly, by using a CuS nanoparticle-conjugated second antibody as the signal tag, the immunoassay for a carcinoembryonic antigen was performed with the detection limit of 0.05 pg mL-1. This smartphone-based double-channel fluorescence device offers the advantages of high sensitivity, inexpensive and miniaturization.
More Related Videos
09:58Computer Numerical Control Micromilling of a Microfluidic Acrylic Device with a Staggered Restriction for Magnetic Nanoparticle-Based Immunoassays
Published on: June 23, 2022
07:13Author Spotlight: High-Quality Quantum Dot Nanobeads for Sensitive Fluorescent Lateral Flow Immunoassays
Published on: June 28, 2024
Related Concept Videos
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
Endocrine Signaling
Fixing Double-strand Breaks
RACE - Rapid Amplification of cDNA Ends
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Channel Rhodopsins
Rhodopsins belong to the family of cell surface proteins called G-protein coupled receptors,...