Bioimaging of isosteric osmium and ruthenium anticancer agents by LA-ICP-MS

Matthias H M Klose1, Sarah Theiner2, Christoph Kornauth3

  • 1Institute of Inorganic Chemistry, University of Vienna, Vienna, Austria and Research Cluster 'Translational Cancer Therapy Research', University and Medical University of Vienna, Vienna, Austria. bernhard.keppler@univie.ac.at samuel.meier@univie.ac.at.

Related Concept Videos

Oxidation of Alkenes: Syn Dihydroxylation with Osmium Tetraoxide02:44

Oxidation of Alkenes: Syn Dihydroxylation with Osmium Tetraoxide

Alkenes are converted to 1,2-diols or glycols through a process called dihydroxylation. It involves the addition of two hydroxyl groups across the double bond with two different stereochemical approaches, namely anti and syn. Dihydroxylation using osmium tetroxide progresses with syn stereochemistry.
13.0K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.4K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
2.1K
Subviral Agents01:29

Subviral Agents

Subviral agents are infectious entities that resemble viruses but lack one or more viral components, such as a capsid or essential replication machinery. These agents include viroids, prions, and satellites, each possessing distinct structural and functional characteristics that influence their mode of infection and replication.Viroids are the simplest subviral agents, consisting of circular, single-stranded RNA molecules without a protein coat. They exclusively infect plants, relying entirely...
589
Air-entraining Agents01:27

Air-entraining Agents

Air-entraining agents improve the durability and workability of concrete in climates with frequent freezing and thawing. These agents prevent cracks by introducing small air bubbles into the mix, creating spaces accommodating water expansion when temperatures drop. The air-entraining agents lower the surface tension of water, forming stable, small air bubbles. This method is more effective than having accidental large voids, as the intentional, smaller, and evenly distributed air voids improve...
278
Masking and Demasking Agents01:19

Masking and Demasking Agents

EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
3.7K