Related Experiment Video
Updated: Feb 13, 2026

Gradient Echo Quantum Memory in Warm Atomic Vapor
Published on: November 11, 2013
Quantitative analysis of hepatic iron in patients suspected of coexisting iron overload and steatosis using
Huimin Lin1, Caixia Fu2, Stephan Kannengiesser3
1Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Background:
The coexistence of hepatic iron and fat is common in patients with hyperferritinemia, which plays an interactive and aggressive role in the progression of diseases (fibrosis, cirrhosis, and hepatocellular carcinomas).
Purpose:
To evaluate a modified high-speed T2 -corrected multi-echo, single voxel spectroscopy sequence (HISTOV) for liver iron concentration (LIC) quantification in patients with hyperferritinemia, with simultaneous fat fraction (FF) estimation.
Study Type:
Retrospective cohort study.
Population:
Thirty-eight patients with hyperferritinemia were enrolled.
Field Strength/Sequence:
HISTOV, a fat-saturated multi-echo gradient echo (GRE) sequence, and a spin echo sequence (FerriScan) were performed at 1.5T.
Assessment:
R2 of the water signal and FF were calculated with HISTOV, and R2* values were derived from the GRE sequence, with R2 and LIC from FerriScan serving as the references.
Statistical Tests:
Linear regression, correlation analyses, receiver operating characteristic analyses, and Bland-Altman analyses were conducted.
Results:
Abnormal hepatic iron load was detected in 32/38 patients, of whom 10/32 had coexisting steatosis. Strong correlation was found between R2* and FerriScan-LIC (R2 = 0.861), and between HISTOV-R2_ water and FerriScan-R2 (R2 = 0.889). Furthermore, HISTOV-R2_ water was not correlated with HISTOV-FF. The area under the curve (AUC) for HISTOV-R2_ water was 0.974, 0.971, and 1, corresponding to clinical FerriScan-LIC thresholds of 1.8, 3.2, and 7.0 mg/g dw, respectively. No significant difference in the AUC was found between HISTOV-R2_ water and R2* at any of the LIC thresholds, with P-values of 0.42, 0.37, and 1, respectively. HISTOV-LIC showed excellent agreement with FerriScan-LIC, with a mean bias of 0.00 ± 1.18 mg/g dw, whereas the mean bias between GRE-LIC and FerriScan-LIC was 0.53 ± 1.49 mg/g dw.
Data Conclusion:
HISTOV is useful for the quantification and grading of liver iron overload in patients with hyperferritinemia, particularly in cases with coexisting steatosis. HISTOV-LIC showed no systematic bias compared with FerriScan-LIC, making it a promising alternative for iron quantification.
Level Of Evidence:
3 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2018.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Multi-species Conserved Sequences
Although the genome of each species varies greatly from each other, a few sequences are highly conserved. Such conserved...
Multi-input and Multi-variable systems
In the absence of...
Multi-Step Reactions
Magnetic Resonance Imaging
Solution Equilibrium and Saturation

