Related Experiment Video
Updated: Feb 13, 2026

Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
Published on: December 27, 2012
Absorb bioresorbable vascular scaffold vs. everolimus-eluting metallic stent in small vessel disease: A propensity
Giuseppe Tarantini1, Giulia Masiero1, Alberto Barioli1
1Department of Cardiac, Thoracic and Vascular Sciences, University of Padua Medical School, Padua, Italy.
Background:
Patients with small vessel disease (SVD) are at higher risk of adverse events after PCI compared to non-SVD patients. In this subset, the use of bioresorbable vascular scaffolds (BVS) has raised particular concern.
Objective:
We aimed to compare outcomes of Absorb BVS versus a 2nd-generation metallic everolimus-eluting stents (EES) in the SVD setting, by pooling patients from three large, prospective studies.
Methods:
Patients with SVD (reference vessel diameter ≤2.75 mm by QCA) and treated with Absorb BVS were identified in the Italian RAI and the MAASSTAD-Absorb registries. EES controls were identified in the COMPARE II Trial. We performed a propensity-score matching using several clinical and angiographic variables. Implantation technique was not object of matching, being device-specific.
Results:
Out of 4635 enrolled subjects, 1147 belonged to the SVD population. After matching, we obtained 337 pairs of patients. High clinical and angiographic complexity was found in both groups. Predilation and postdilation rates were significantly higher in BVS patients. No differences were found in terms of the device-oriented composite end-point at 1-year (HR = 1.08, 95%CI 0.5-2.3, P = .8) and 2-years (HR = 1.28, 95% CI: 0.68-2.43, P = .5). Notwithstanding, higher incidence of definite/probable stent thrombosis was observed in the BVS group at 1 year (HR 4.7, 95%CI 0.8-31.4, P = .08) and 2-years (HR = 8.34 95%CI 1.1-60.2, P = .04).
Conclusion:
In this propensity-matched analysis pooling SVD patients of three large prospective studies, incidence of composite device-related events was comparable between BVS and EES up to 2 years follow-up. However, higher rates of stent thrombosis were found in the BVS group.
Related Concept Videos
Comparing the Survival Analysis of Two or More Groups
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Alkali Metals
Table 1: Properties of the alkali metals
Imaging Studies VII: Vascular Imaging