Patellofemoral Imbalance in a Balanced Total Knee Arthroplasty: How Does it Occur?
Perry Jaymes Evangelista1, Nathan Lenz2, Scott Laster2
1Department of Orthopaedic Surgery, New York University Langone Medical Center, New York, New York.
Abstract:
Despite the overall successful outcomes following primary total knee arthroplasty (TKA) and the concept that a well-balanced TKA yields a more successful result, concerns still remain in the reported literature regarding the patellofemoral joint. Diminished outcomes have been associated with poorly balanced or placed patella implants. The effect of different techniques to achieve flexion-extension balance and the use of posterior stabilized (PS) versus cruciate retaining (CR) implant designs on patellofemoral balancing has not been previously studied. The purpose of this study is to utilize a validated computational analysis software to simulate the effects of varying implant positions and sizes of femoral components. The patellofemoral retinaculum (PFR) load was significantly affected by some conditions, while others did not reach significance. The proximal-distal implant position with knee flexion angle (p < 0.001), the implant size (p < 0.001), and the implant bearing type (CR/PS) (p < 0.05) were significant. For the proximal-distal implant position and knee flexion angle, a more proximal implant position (elevating the joint line) increased the PFR load from 15 to 30°, and a more proximal implant position reduced retinaculum load from 60 to 135°. However, at 45°, implant position does not affect retinaculum load. Achieving the appropriate balance between the dynamic nature of both the tibiofemoral and the patellofemoral interaction in TKA has proven to be complex and challenging to manage. Balancing of a TKA is essential to the proper functioning and overall longevity of the implant. These results demonstrate that patellofemoral balance is affected by implant size and position during flexion-extension gap balancing.
Related Concept Videos
Homeostatic Imbalance
However, sometimes these feedback loops fail,...
Balancing Redox Equations
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Homeostatic Imbalances in Body Temperature
Regulation of Expression Occurs at Multiple Steps
Transcription results in the generation of precursor (pre-mRNA) that consists of both exons and introns, which needs further processing before being translated to a...
Regulation of Expression Occurs at Multiple Steps