Prospective study of bilateral mix-and-match implantation of diffractive multifocal intraocular lenses in Koreans
Chan Min Yang1, Dong Hui Lim1,2, Sungsoon Hwang1
1Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, #81 Irwon-ro, Gangnam-gu, Seoul, 06351, South Korea.
Background:
To evaluate monocular and binocular visual outcomes for near, intermediate, and far distance in patients implanted with diffractive multifocal intraocular lenses (IOLs) with different add power contralaterally.
Methods:
This is a prospective contralateral study. Two diffractive multifocal IOLs with different added power were implanted bilaterally in twenty patients. TECNIS® ZKB00 (+ 2.75 D) was implanted in a dominant eye, and TECNIS® ZLB00 (+ 3.25 D) was implanted in a non-dominant eye. Uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), and manifest refraction (MR) values were measured at 1 month and 3 months postoperatively. At the 3-month follow-up, defocus curve, contrast sensitivity, and reading performance were evaluated. Quality of vision, overall satisfaction, and spectacle independence were evaluated by questionnaire.
Results:
Postoperative binocular UDVA, visual acuity at 80 cm, 60 cm, 50 cm, 43 cm, 33 cm were - 0.08 ± 0.10, 0.12 ± 0.14, 0.09 ± 0.09, 0.07 ± 0.11, 0.14 ± 0.09, 0.25 ± 0.11 logMAR. The binocular defocus curve showed an extended range of good visual acuity with sharp vision being observed from 0 D to - 2.50 D defocus (logMAR≤0.1). Reading performance was significantly improved compared to baseline. All patients were spectacle-free at distance, and 94.74% of the patients did not require glasses for near and intermediate vision.
Conclusions:
Mix-and-match implantation of diffractive multifocal IOLs with different add power provides an excellent wide range of vision, as well as high levels of visual quality and patient satisfaction.
Trial Registration:
ClinicalTrials.gov , NCT02556944, https://clinicaltrials.gov/show/NCT02556944.
Related Concept Videos
Interference and Diffraction
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Wilcoxon Signed-Ranks Test for Matched Pairs
Mixing Concrete
Mixing Time