Related Experiment Video
Updated: Feb 13, 2026

Electrochemotherapy of Tumours
Published on: December 15, 2008
High-Frequency Jet Ventilation During Cryoablation of Small Renal Tumours
Thea Buchan1, Miles Walkden1, Kathryn Jenkins2
1Imaging Department, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK.
Aim:
To evaluate the effect of high-frequency jet ventilation (HFJV) in place of standard intermittent positive-pressure ventilation (IPPV) on procedure duration, patient radiation dose, complication rates, and outcomes during CT-guided cryoablation of small renal tumours.
Materials And Methods:
One hundred consecutive CT-guided cryoablation procedures to treat small renal tumours under general anaesthesia were evaluated-50 with standard IPPV and 50 after the introduction of HFJV as standard practice. Anaesthesia and procedural times, ionising radiation dose, complications, and 1-month post-treatment outcomes were collected.
Results:
HFJV was feasible and safe in all cases. Mean procedure time and total anaesthetic time were shorter with HFJV (p = <0.0001). The number of required CT acquisitions (p = 0.0002) and total procedure patient radiation dose (p = 0.0027) were also lower in the HFJV group compared with the IPPV group. There were a total of four complications of Clavien-Dindo classification 3 or above-three in the IPPV group and one in the HFJV group. At 1-month follow-up, two cases (both in the IPPV group) demonstrated subtotal treatment. Both cases were subsequently successfully retreated with cryoablation.
Conclusion:
By reducing target tumour motion during CT-guided renal cryoablation, HFJV can reduce procedure times and exposure to ionising radiation. HFJV provides an important adjunct to complex image-guided interventions, with potential to improve safety and treatment outcomes.
Related Concept Videos
Free Jet
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Frequency-dependent Selection
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...