Etoposide-Loaded Poly(Lactic-co-Glycolic Acid) Intravitreal Implants: In Vitro and In Vivo Evaluation

Ana Gabriela Reis Solano1, Adriana de Fátima Pereira2, Luiz Gustavo Amorim de Faria2

  • 1Faculty of Pharmacy, Federal University of São João del-Rei, Divinópolis, MG, Brazil. anagabriela@ufsj.edu.br.

AAPS Pharmscitech
|March 9, 2018
PubMed

Related Concept Videos

Equivalence: In Vitro and In Vivo Bioequivalence01:17

Equivalence: In Vitro and In Vivo Bioequivalence

Body:Bioequivalence studies are crucial in evaluating whether new drugs can match an approved one regarding pharmacological effects and clinical performance. These studies test if drugs, despite different dosage forms, share identical plasma concentration-time profiles. Three types of equivalence are central to these studies: chemical, pharmaceutical, and therapeutic. Chemical equivalence indicates that two or more drug products contain identical active ingredients in equal amounts.
243
Impact Loading01:19

Impact Loading

Impact loading occurs when a moving object collides with a stationary structure, such as a rod with a uniform cross-sectional area fixed at one end. Under these conditions, the rod absorbs the kinetic energy from the striking object, leading to deformation and subsequent stress development. As the rod returns to its original position and reaches maximum stress, the absorbed energy, initially manifested as kinetic energy, transforms entirely into strain energy.
In cases of elastic deformation,...
720
Drug Product Performance: In Vitro–In Vivo Correlation01:20

Drug Product Performance: In Vitro–In Vivo Correlation

In pharmaceutical development, it's crucial to establish a predictive in vitro–in vivo correlation (IVIVC) for two or more formulations to gain a comprehensive understanding of release properties. IVIVC reduces the need for costly in vivo studies and facilitates the establishment of meaningful dissolution specifications with significant cost savings and decreased regulatory burden. Furthermore, a meaningful IVIVC should predict Cmax and AUC within 20%, aligning with FDA guidance while...
288
Distributed Loads01:19

Distributed Loads

Distributed loads are a common type of load that engineers and scientists encounter in various practical situations. Distributed loads often refer to a type of load spread over a surface or a structure and can be modeled as continuous force per unit area.
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
981
Eccentric Loading01:16

Eccentric Loading

Eccentric loading is a crucial concept in the study of structural engineering and mechanics, particularly when analyzing the stability and stress distribution in columns. Unlike centric loading, where the force is applied along the centroidal axis, causing uniform compression, eccentric loading occurs when a force is applied off-center. This off-center application introduces not only direct compressive stress but also bending stress, significantly influencing the column's behavior under...
1.0K
Amino acids03:42

Amino acids

Amino acids are the monomers that comprise proteins. Each amino acid has the same fundamental structure, which consists of a central carbon atom, or the alpha (α) carbon, bonded to an amino group (NH2), a carboxyl group (COOH), and to a hydrogen atom. Every amino acid also has another atom or group of atoms bonded to the central atom known as the R group. There are 20 common amino acids present in proteins, each with a different R group. Variation in the amino acid sequence is responsible for...
106.4K