Arteriotomy site complication during transcatheter aortic valve replacement: Ipsilateral wire protection and bailout
Edo Kaluski1, Safi U Khan1, Sudhakar Sattur1
1Division of Cardiovascular Disease, Robert Packer Hospital and the Guthrie Health Services, Sayre, PA, USA; The Geisinger Commonwealth School of Medicine, Scranton, PA, USA.
Abstract:
Major vascular complications still occur in ~4.2% of transcatheter aortic valve replacement (TAVR) procedures. These complications are a major safety drawback of TAVR when compared to surgical aortic valve replacement (SAVR). Contemporary strategies designed to minimize and effectively treat vascular complications are of immense importance to a successful TAVR program. This review discusses strategies to optimize TAVR access and device choice along with TAVR access complication management. Iliac complications are less frequently encountered and can be managed effectively via the TAVR sheath over the TAVR wire employing ipsilateral proximal iliac balloon occlusion and endovascular repair. The more common arteriotomy site complications and access site closure failure require prophylactic or bail-out common femoral to superficial femoral artery wiring. Suggested is a novel method of ipsilateral arteriotomy site protection that is safe, simple and does not require additional resources. Ipsilateral wiring can also be done prophylactically or as a bailout in case of arteriotomy site complication.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Hemodialysis II: Procedure and Complications
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Magnetic Field Due to Two Straight Wires
Household Wiring And Electrical Safety
Magnetic Field Due To A Thin Straight Wire
Pneumonia III: Complications and Assessment