Related Experiment Video
Updated: Feb 13, 2026

Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
Cost-Effectiveness Analysis of Syndesmotic Screw Versus Suture Button Fixation in Tibiofibular Syndesmotic Injuries
Duncan C Ramsey1, Darin M Friess
1Department of Orthopaedics and Rehabilitation, Oregon Health and Science University, Portland, OR.
Objectives:
To evaluate the cost effectiveness of suture buttons compared with syndesmotic screws for repair of tibiofibular syndesmotic injuries.
Methods:
A decision tree model was constructed to describe outcomes after syndesmosis repair using suture buttons and syndesmotic screws from the perspective of a capitated health care system. Outcomes were uneventful healing, removal of symptomatic implants, deep infection, and persistent diastasis requiring revision. Weighted literature averages were used to estimate variables for a baseline model. Outcomes were measured in quality adjusted life years. Procedure and implant costs were derived from Medicare reimbursement rates and the University Health System Consortium. An incremental cost-effectiveness ratio threshold of $50,000 per quality-adjusted life years was used to evaluate cost effectiveness.
Results:
The baseline model did not identify suture buttons to be cost effective. Sensitivity analysis demonstrates the model to be exquisitely sensitive to small changes in reoperation rates and implant price. At median University Health System Consortium implant prices, if the removal rate for symptomatic screws is below 13.7%, then screws are cost effective. If the screw removal rate is greater than 17.5%, then a suture button is cost effective. Within this interval, detailed analysis of the model suggests that screws may be the cost-effective strategy, but that determination should be taken with caution.
Conclusions:
Moving away from the practice of routinely removing all syndesmotic screws has changed the financial landscape of syndesmosis repair. At their median cost, suture buttons are likely to be cost effective over screws for symptomatic screw removal rates greater than 17.5%. Cost effectiveness is sensitive to changes in implant removal rates and the number of devices used per patient.
Level Of Evidence:
Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Carbon-dioxide Fixation

