Related Experiment Video
Updated: Feb 13, 2026

A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
Published on: January 13, 2026
Effectiveness of an Arthroscopic Technique to Correct Supination Losses of 90° or More
Francisco Del Piñal1, Eduardo Moraleda1, Jaime S Rúas1
1Private Practice, Madrid, Spain.
Purpose:
To present a new arthroscopic method for treating supination losses.
Methods:
Six patients (15-71 y) were eligible for this study. All had a history of trauma to the wrist more than 6 months previously. Five of them had sustained a distal radius fracture: 3 had been treated with a volar plate (1 of them for an extra-articular malunion), 1 with an external fixator and K-wires, and 1 had been treated in a cast. One of these patients underwent a further operation for correcting an intra-articular malunion. The last patient underwent an open reduction of a transscaphoid perilunate dislocation. During a standard radiocarpal arthroscopy, a curved periosteal elevator was inserted through the 6R portal into the volar-radial corner of the triangular fibrocartilage complex and advanced proximally gliding on the anterior ulnar head surface. The volar capsule was then distended with the periosteal elevator and by means of gentle sweeping motion adherences between them, the volar capsule and the ulnar head were freed. Finally, the arthroscopic release was combined with a gentle passive supination force applied by the surgeon. Full supination was maintained in an orthosis for 2 to 3 days. Afterward, regular physical therapy was instituted. Concomitant surgery, arthroscopic or open, was performed in all to treat associated conditions.
Results:
Full supination (90°) was achieved in all intraoperatively. At a mean follow-up of 3.3 years, mean supination was 76° in the latest follow-up (range, 50° to 90°). Mean improvement in supination was 80° (range, 50° to 100°). No distal radioulnar instability or other complications were noted.
Conclusions:
The method presented proved effective in severe forms of supination deficits.
Type Of Study/Level Of Evidence:
Therapeutic V.
Related Concept Videos
Distance Corrections
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Power Factor Correction
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...