Bioimpedance analysis is safe in patients with implanted cardiac electronic devices
Xavier Chabin1, Ouarda Taghli-Lamallem1, Aurélien Mulliez2
1Université Clermont Auvergne, Cardio Vascular Interventional Therapy and Imaging (CaVITI), Image Science for Interventional Techniques (ISIT), UMR6284, and CHU Clermont-Ferrand, Cardiology Department, F-63003 Clermont-Ferrand, France.
Background & Aims:
There is an increase in the number of patients worldwide with cardiac implantable electronic devices (CIEDs). Current medical practice guidelines warn against performing bioimpedance analysis (BIA) in this group of patients in order to avoid any electromagnetic interference. These recommendations restrict using the BIA in patients undergoing heart failure or with nutrition disorders in whom BIA could be of major interest in detecting peripheral congestion and to help guide treatment. The present study was conducted to evaluate whether BIA caused electromagnetic interference in patients having CIEDs.
Methods:
Patient enrollment was conducted during routine face-to-face consultations for scheduled CIEDs interrogations. Device battery voltage, lead impedance, pacing thresholds and device electrograms were recorded before and after each BIA measurement to detect any electromagnetic interference or oversensing.
Results:
A total of 200 patients were enrolled. During BIA, no significant changes in battery voltage, lead impedance or pacing thresholds were detected, nor were there any inappropriate over- or undersensing observed in intracardiac electrograms. Furthermore, 6- and 12-month follow-up did not reveal any changes in CIEDs.
Conclusions:
This study shows no interference in patients equipped with CIEDs and suggests that BIA can be securely performed in these patients. Trial registered under the identifier NCT03045822.
More Related Videos
Related Concept Videos
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Electron Affinity
Electron Behavior
Electrons are negatively charged subatomic particles that are attracted to an orbit around the positively-charged nucleus of an atom. They reside in locations that are associated with energy levels called shells and are further organized into sub-shells and orbitals within each shell.
Electrons Orbit the Nucleus
Electrons are found in specific locations outside of the nucleus. The shell in which an electron resides indicates the general energy level of the electron: those closer to the...
Electron Transport Chains
The ETC is comprised of...