Related Experiment Video
Updated: Feb 13, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Abdominal Attenuation Values on Virtual and True Unenhanced Images Obtained With Third-Generation Dual-Source
Pierre Durieux1, Pierre Alain Gevenois1, Alain Van Muylem2
11 Department of Radiology, Hôpital Erasme, Université libre de Bruxelles, Rte de Lennik 808, B-1070 Brussels, Belgium.
Objective:
The purpose of this study is to investigate the magnitude of differences between attenuation values measured on virtual unenhanced images and true unenhanced images obtained using third-generation dual-source dual-energy CT (DECT).
Subjects And Methods:
A total of 83 patients requiring thoracoabdominal CT for cancer workup were included in this prospective study. CT examinations included true unenhanced acquisitions (tube potential, 120 kVp) and arterial and portal phase dual-energy CT (DECT) acquisitions (tube potential, 100 kVp and Sn 150 kVp [where Sn denotes the interposition of a tin filter in the high-energy beam]; tube current-exposure time product, 190 and 95 mAs). Virtual unenhanced images were created using two commercially available DECT postprocessing algorithms, one of which was designed to create liver images (hereafter referred to as VNC1 images) and the other of which was designed to create images of organs containing minor amounts of fat (hereafter referred to as VNC2 images). Attenuation values on the liver, spleen, paraspinal muscles, retroperitoneal fat, renal cortex and medulla, and gallbladder and bladder lumens were measured.
Results:
The attenuation values of all tissues were significantly different between virtual unenhanced and true unenhanced images (p = < 0.001-0.042), except for the liver and spleen in the portal phase and muscles in both phases. When statistically significant, correlations between these differences and body mass index (weight in kilograms divided by the square of height in meters) depended on the tissue imaged and algorithm used. The percentage of cases in which these differences were 10 HU or greater was 1% for the liver and approximately 5% for the spleen and muscles, regardless of the algorithm and phase, but on VNC1 images it reached approximately 30% for the kidney, 70% for the gallbladder and bladder, and depending on the phase, 40-70% for fat. On VNC2 images, the percentage of cases in which these differences were 20 HU or greater was approximately 90% for fat.
Conclusion:
Abdominal virtual unenhanced images obtained with third-generation dual-source DECT still should not replace true unenhanced images because of substantial differences in attenuation measurements for fluid, fat, and renal tissues.
Related Concept Videos
True Stress and True Strain
In contrast, true stress offers a more precise portrayal. It is computed by dividing the...
Dual Nature of Electromagnetic (EM) Radiation
Wavelength is the distance between two consecutive peaks (the highest point) or troughs (the lowest point) in the wave. Frequency is the number of...
Biodiversity and Human Values
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
Imaging Studies for Cardiovascular System V: CT

