Related Experiment Video
Updated: Feb 13, 2026

Photoconversion of Purified Fluorescent Proteins and Dual-probe Optical Highlighting in Live Cells
Published on: June 26, 2010
High-sensitivity optical to microwave comparison with dual-output Mach-Zehnder modulators
Mamoru Endo1, Tyko D Shoji1, Thomas R Schibli2,3
1Department of Physics, The University of Colorado, Boulder, Colorado, 80309-0390, USA.
Abstract:
We demonstrate the use of two dual-output Mach-Zehnder modulators (DO-MZMs) in a direct comparison between a femtosecond (fs) pulse train and a microwave signal. Through balanced detection, the amplitude-to-phase modulation (AM-PM) conversion effect is suppressed by more than 40 dB. A cross-spectrum technique enables us to achieve a high-sensitivity phase noise measurement (-186 dBc/Hz above 10-kHz offset), which corresponds to the thermal noise of a +9 dBm carrier. This method is applied to compare a 1-GHz fs monolithic laser to a 1-GHz microwave signal generated from photodetection of a free-running 500 MHz mode-locked laser. The measured phase noise is -160 dBc/Hz at 4-kHz, -167 dBc/Hz at 10-kHz, and -180 dBc/Hz at offset frequencies above 100-kHz. The measurement is limited by the free-running 500-MHz laser's noise, the flicker noise of the modified uni-traveling carrier photodiode and the thermal noise floor, not by the method itself. This method also has the potential to achieve a similar noise floor even at higher carrier frequencies.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Regulation of Water Output

