Related Experiment Video
Updated: Feb 13, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Combined pedicle screw fixation at the fracture vertebrae versus conventional method for thoracolumbar fractures: A
1Department of Nephrology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Ave, Wuhan 430030, Hubei, China.
Background:
Thoracolumbar fractures is a frequent injury occurring in spinal trauma. Outcomes and complications between combined pedicle screw fixation at the fracture vertebrae (AFV) and conventional method cross the fracture vertebrae (CFV) are still controversial. Thus, this study aimed to evaluate differences in outcome variables between these two operative methods.
Materials And Methods:
PubMed, Web of Science, Cochrane Library, EMBASE and CNKI were searched with the terms "thoracolumbar fractures", "posterior", "pedicle screw fixation", and "clinical trial" from Jan 1980 to July 2017. Two reviewers independently screened the studies for eligibility, evaluated the quality and extracted data from eligible studies, with confirmation by cross-checking. The major results and conclusions were concluded, and the different complication rates and functional outcomes were compared. Meta-analysis was performed using RevMan 5.3 software.
Results:
Eighteen randomized controlled trials involving 1280 patients were eligible. The pooled data revealed that AFV group might be associated with more intraoperative blood loss (MD = 9.84, 95%CI 7.45 to 12.22) and longer operation time (MD = 1.97, 95%CI 0.17 to 3.77) when compared with CFV group. However, AFV group significantly improved visual analogue scale (VAS) (MD = -1.27, 95%CI -1.70 to -0.83), anterior vertebral height (AVH) (MD = 7.58, 95%CI 3.99 to 11.17), short-term Cobb angle (MD = -1.29, 95%CI -2.39 to -0.19), long-term Cobb angle (MD = -4.47, 95%CI -7.30 to -1.63) and loss of long-term correction efficacy (MD = -6.56, 95%CI -7.49 to -5.62) after surgery. Moreover, compared with the CFV group, the AFV group had lower rate of implant failure (MD = 0.16, 95%CI 0.07 to 0.36). Both techniques had similar hospital stay (MD = 0.25, 95%CI -0.52 to 1.03) and postoperative infection (MD = 0.53, 95%CI 0.13 to 2.23).
Conclusions:
Though with a more operation time and intraoperative hemorrhage, combined pedicle screw fixation at the fracture veterbrae may be better than traditional fixation cross the fracture level alone for thoracolumbar fractures.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
General Structure of a Vertebra
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...

