Assessment of cerebral blood flow in neonates and infants: A phase-contrast MRI study

Peiying Liu1, Ying Qi2, Zixuan Lin1

  • 1Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.

Neuroimage
|March 15, 2018
PubMed

Insights

Phase-contrast MRI enables accurate cerebral blood flow (CBF) measurement in infants. This study provides age-specific recommendations for optimizing CBF quantification in neonates and young children.

Area of Science:

  • Medical Imaging
  • Pediatric Neurology
  • Cardiovascular Physiology

Background:

  • Abnormal cerebral blood flow (CBF) is linked to neonatal and infant diseases.
  • Current CBF measurement methods like arterial spin labeling (ASL) have limitations in young children due to low signal-to-noise ratio (SNR) and quantification challenges.
  • Rapid physiological changes in infants complicate the selection of MRI sequence parameters.

Purpose of the Study:

  • To apply and validate phase-contrast (PC) MRI for quantifying CBF in neonates and infants up to 18 months of age.
  • To establish reliable methods for measuring CBF in a pediatric population where it is clinically challenging.
  • To provide age-specific guidance for optimizing PC-MRI parameters for infant brain imaging.

Main Methods:

  • Compared time-of-flight (TOF) MR angiogram implementations for visualizing brain arteries.
  • Measured flow velocity and CBF in the internal carotid artery (ICA) and vertebral artery (VA) using PC-MRI with multiple encoding velocities (Venc) in 21 subjects.
  • Analyzed age-related changes in CBF relative to brain volume.

Main Results:

  • Peak arterial flow velocity in the ICA increased from 10.2 cm/s at birth to 56.0 cm/s at 18 months.
  • Peak VA flow velocity ranged from 4.5 to 36.3 cm/s during the same period.
  • CBF showed a significant age-related increase (p < 0.001) from 13.1 to 84.7 ml/100g/min within the first 18 months.

Conclusions:

  • PC-MRI is a promising technique for reliable global CBF assessment in infants.
  • The study provides crucial data on CBF development in early life and age-specific Venc recommendations for PC-MRI.
  • This work may establish a foundation for accurate whole-brain CBF measurement in pediatric populations.

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
14.4K
Blood Flow01:29

Blood Flow

Blood is pumped by the heart into the aorta, the largest artery in the body, and then into increasingly smaller arteries, arterioles, and capillaries. The velocity of blood flow decreases with increased cross-sectional blood vessel area. As blood returns to the heart through venules and veins, its velocity increases. The movement of blood is encouraged by smooth muscle in the vessel walls, the movement of skeletal muscle surrounding the vessels, and one-way valves that prevent backflow.
76.2K
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
921
Autoregulation of Blood Flow01:17

Autoregulation of Blood Flow

Autoregulation mechanisms are characterized by their inherent capacity for self-regulation without necessitating specific nervous stimulation or endocrine control. These mechanisms facilitate the adjustment of blood flow and, therefore, perfusion specific to each tissue region. This self-regulation encompasses chemical signals and myogenic controls.
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
8.2K
Applications of Integration to Find Blood Flow01:27

Applications of Integration to Find Blood Flow

Blood flow through a cylindrical blood vessel can be mathematically described using the principles of laminar flow, a regime in which fluid moves smoothly in parallel layers. In this model, the velocity of the blood is not uniform across the cross-section of the vessel; rather, it varies with the radial distance from the center. The maximum velocity occurs along the central axis, decreasing progressively toward the vessel walls, where it reaches zero due to viscous drag.Approximating Blood...
60
Phase Transitions02:31

Phase Transitions

Whether solid, liquid, or gas, a substance's state depends on the order and arrangement of its particles (atoms, molecules, or ions). Particles in the solid pack closely together, generally in a pattern. The particles vibrate about their fixed positions but do not move or squeeze past their neighbors. In liquids, although the particles are closely spaced, they are randomly arranged. The position of the particles are not fixed—that is, they are free to move past their neighbors to...
23.3K