Related Experiment Video
Updated: Feb 13, 2026

Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements
Published on: June 25, 2021
Measurement of a True [Formula: see text]O2max during a Ramp Incremental Test Is Not Confirmed by a Verification
Juan M Murias1, Silvia Pogliaghi2, Donald H Paterson3
1Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada.
Abstract:
The accuracy of an exhaustive ramp incremental (RI) test to determine maximal oxygen uptake ([Formula: see text]O2max) was recently questioned and the utilization of a verification phase proposed as a gold standard. This study compared the oxygen uptake ([Formula: see text]O2) during a RI test to that obtained during a verification phase aimed to confirm attainment of [Formula: see text]O2max. Sixty-one healthy males [31 older (O) 65 ± 5 yrs; 30 younger (Y) 25 ± 4 yrs] performed a RI test (15-20 W/min for O and 25 W/min for Y). At the end of the RI test, a 5-min recovery period was followed by a verification phase of constant load cycling to fatigue at either 85% (n = 16) or 105% (n = 45) of the peak power output obtained from the RI test. The highest [Formula: see text]O2 after the RI test (39.8 ± 11.5 mL·kg-1·min-1) and the verification phase (40.1 ± 11.2 mL·kg-1·min-1) were not different (p = 0.33) and they were highly correlated (r = 0.99; p < 0.01). This response was not affected by age or intensity of the verification phase. The Bland-Altman analysis revealed a very small absolute bias (-0.25 mL·kg-1·min-1, not different from 0) and a precision of ±1.56 mL·kg-1·min-1 between measures. This study indicated that a verification phase does not highlight an under-estimation of [Formula: see text]O2max derived from a RI test, in a large and heterogeneous group of healthy younger and older men naïve to laboratory testing procedures. Moreover, only minor within-individual differences were observed between the maximal [Formula: see text]O2 elicited during the RI and the verification phase. Thus a verification phase does not add any validation of the determination of a [Formula: see text]O2max. Therefore, the recommendation that a verification phase should become a gold standard procedure, although initially appealing, is not supported by the experimental data.
Related Concept Videos
Confirmation Biases
True Stress and True Strain
In contrast, true stress offers a more precise portrayal. It is computed by dividing the...
Self-Evaluation: Self-Enhancement and Self-Verification
Chemical Formulas
Ionic Compounds: Formulas and Nomenclature
Molecular Compounds: Formulas and Nomenclature

