Assessment of Effective Dose Associated with Coronary Computed Tomography Angiography in Isfahan Province, Iran
Mohammadbagher Tavakoli1, Reihane Faraji1, Zahra Alirezaei1
1Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Abstract:
Computed tomography coronary angiography (CTCA) has generated a great interest over the past two decades, due to its high diagnostic accuracy and efficacy in the assessment of patients having coronary artery disease. This method is associated with high radiation dose and this has raised serious concerns in the literature. Effective dose (E) is a single parameter meant to reflect the relative risk from exposure to ionizing radiation. Therefore, it is necessary to calculate this parameter to indicate ionizing radiation relative risk. The aim of this study was to calculate the effective dose from 64-slice CTCA in Isfahan. To calculate the effective dose, an ionization chamber and a body phantom with diameter of 32 cm and length of 15 cm were used. CTCA radiation conditions commonly used in two centers were applied for this work. For all scans, computed tomography volume dose index (CTDIv), dose-length product (DLP), and effective dose were obtained using dose-length-product method. The obtained CTDIv, DLP, and effective dose were compared in two centers, and mean, maximum, and minimum values of effective dose for heart coronary CT angiography (CCTA) examinations and calcium score were compared with other studies. The amount of average, maximum, and minimum effective doses for heart CCTA examinations in two centers are 4.65 ± 0.06, 6.0489, and 3.492 mSv, respectively, and for calcium score test are, 1.04 ± 0.04, 2.155, and 0.98 mSv, respectively. CTDIv, DLP, and effective dose values did not show any significant difference in two centers. Although the effective dose of CTCA and calcium score was lower than that of other studies, it is reasonable to reduce the effective dose to the minimum possible value to reduce the risk of cancer associated with ionizing radiation. The results of this study can be used to introduce the effective dose as a local diagnostic reference dose (DRL) for CTCA examinations in Isfahan Province.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Biological Effects of Radiation
Dose Size and Dosing Frequency: Determination Methods