A Simple Approach to Determine a Curve Fitting Model with a Correct Weighting Function for Calibration Curves in

Yuhong Xiang1, Jean Donley1, Elena Seletskaia1

  • 1Pfizer Worldwide Research & Development, Biomedicine Design, 1 Burtt Rd, Andover, Massachusetts, 01810, USA.

The AAPS Journal
|March 15, 2018
PubMed

Related Concept Videos

Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
5.0K
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
4.5K
Ligand Binding Sites02:40

Ligand Binding Sites

Proteins are dynamic macromolecules that carry out a wide variety of essential processes; however, the activities of most proteins depend on their interactions with other molecules or ions, known as ligands.
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
15.2K
Ligand Binding and Linkage00:49

Ligand Binding and Linkage

Allosteric proteins have more than one ligand binding site; the binding of a ligand to any of these sites influences the binding of ligands to the other sites. When a protein is allosteric, its binding sites are called coupled or linked.  In the case of enzymes, the site that binds to the substrate is known as the active site and the other site is known as the regulatory site. When a ligand binds to the regulatory site, this leads to conformational changes in the protein that can influence...
5.6K
Heating and Cooling Curves02:44

Heating and Cooling Curves

When a substance—isolated from its environment—is subjected to heat changes, corresponding changes in temperature and phase of the substance is observed; this is graphically represented by heating and cooling curves.
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
28.1K
Acid-Base Titration Curves02:23

Acid-Base Titration Curves

A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of...