Related Experiment Video
Updated: Feb 13, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Determination of risk factors for pacemaker requirement following rapid-deployment aortic valve replacement
Parwis B Rahmanian1, Kaveh Eghbalzadeh1, Süreyya Kaya1
1Department of Cardiothoracic Surgery, Heart Center, University Hospital Cologne, Cologne, Germany.
Objectives:
Rapid-deployment aortic valve replacement (RD-AVR) potentially reduces procedure times providing excellent haemodynamic results compared to standard tissue aortic valve replacement. However, concerns have been raised regarding higher rates of postoperative pacemaker (PPM) requirement compared to standard aortic valve replacement. In this study, we sought to determine the PPM rate and its potential risk factors in RD-AVR patients.
Methods:
Between 2011 and 2017, 193 patients underwent RD-AVR. The main outcome investigated was PPM. Other outcome parameters included hospital mortality, major morbidity, length of stay and discharge condition. Predictors of PPM were determined using multivariable regression models.
Results:
Isolated RD-AVR was performed in 72 (37%) patients and 121 (63%) patients underwent combined RD-AVR [coronary artery bypass grafting (n = 110), mitral repair (n = 6) and others (n = 5)]. Aortic cross-clamp and cardiopulmonary bypass times were 57.1 ± 25.1 min and 90.0 ± 40.1 min in the overall RD-AVR population and 39.4 ± 13.5 min and 67.6 ± 24.5 min, respectively, in isolated RD-AVR procedures. PPM occurred in 20 (10.4%) patients. Multivariable analysis revealed bypass grafting of the circumflex artery [odds ratio = 2.8] and preoperative right branch bundle block (odds ratio = 11.7) as independent predictors for PPM.
Conclusions:
RD-AVR is a safe and simple procedure resulting in favourable short aortic cross-clamp and cardiopulmonary bypass times and considerable low gradients in postoperative echocardiography. PPM following isolated RD-AVR remains in the range of standard aortic valve replacement. However, patients undergoing concomitant coronary artery bypass grafting, particularly of the circumflex artery, face a 3-fold increased risk for PPM implantation enhanced if right branch bundle block is present. Follow-up examination is necessary to determine whether these patients remain pacer dependent during long-term follow-up.
More Related Videos
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Drug Toxicity: Risk factors
Transcription Factors
Requirements for Human Life
Oxygen
Atmospheric air is only about 20 percent oxygen, but that oxygen is a key component of the chemical reactions that keep the body alive, including the reactions that produce ATP. Brain cells are susceptible to a lack of oxygen because they require a...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Relative Risk