THE USE OF INTERFERENCE REFLECTION CONTRAST IN THE EXAMINATION OF DIATOM VALVES
1Botany Department, Connecticut College, New London, Connecticut 06430Micro Laboratory, Leica Inc., Allendale, New Jersey 07401.
Abstract:
Even though scanning electron microscopy (SEM) is now needed to identify some species of diatoms, the majority of identifications and quantification of these organisms in ecological works is accomplished with a light microscope, using transmitted light optical methods. In this paper we demonstrate the use of interference reflection contrast (incident light) for the examination of diatoms, a method that significantly improves the resolution of structural detail, and therefore, identification of diatom taxa with light microscopy. Using incident light we were routinely able to distinguish between structures that were close to the theoretical limit of resolution for visible light, and that were not resolvable with such standard transmitted light techniques as phase contrast and differential interference contrast (DIC). Light microscopes with epi-illumination light paths can be easily and inexpensively outfitted to use this simple technique.
Abbreviations:
DIC, differential interference contrast; IRC, interference reflection contrast; LM, light microscopy.
More Related Videos
09:45Implementation of Interference Reflection Microscopy for Label-free, High-speed Imaging of Microtubules
Published on: August 8, 2019
06:43Simultaneous Interference Reflection and Total Internal Reflection Fluorescence Microscopy for Imaging Dynamic Microtubules and Associated Proteins
Published on: May 3, 2022
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Interference and Diffraction
RNA Interference
This process occurs naturally in cells, often through the activity of genomically-encoded microRNAs. Researchers can take advantage of this mechanism by introducing synthetic RNAs to deactivate specific genes for research or therapeutic purposes. For example, RNAi could be used...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Reflection of Waves
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...