Comparison of three haemodynamic monitoring methods in comatose post cardiac arrest patients
Henrik Staer-Jensen1, Kjetil Sunde1,2, Espen Rostrup Nakstad3
1a Department of Anaesthesiology, Division of Emergencies and Critical Care , Oslo University Hospital , Oslo , Norway.
Objectives:
Haemodynamic monitoring during post arrest care is important to optimise treatment. We compared stroke volume measured by minimally-invasive monitoring devices with or without thermodilution calibration, and transthoracic echocardiography (TTE), and hypothesised that thermodilution calibration would give stroke volume index (SVI) more in agreement with TTE during targeted temperature management (TTM).
Design:
Comatose out-of-hospital cardiac arrest survivors receiving TTM (33 °C for 24 hrs) underwent haemodynamic monitoring with arterial pulse contour analyses with (PiCCO2®) and without (FloTrac®/Vigileo® monitor®) transpulmonary thermodilution calibration. Haemodynamic parameters were collected simultaneously every fourth hour during TTM (hypothermia) and (normothermia). SVI was measured with TTE during hypothermia and normothermia. Bland-Altman analyses were used for determination of SVI bias (±1SD).
Results:
Twenty-six patients were included, of whom 77% had initial shockable rhythm and 52% discharged with good outcome. SVI (bias ±2SD) between PiCCO (after thermodilution calibration) vs FloTrac/Vigileo, TTE vs FloTrac/Vigileo and TTE vs PiCCO were 1.4 (±25.8), -1.9 (±19.8), 0.06 (±18.5) ml/m2 during hypothermia and 9.7 (±23.9), 1.0 (±17.4), -7.2 (±12.8) ml/m2 during normothermia. Continuous SVI measurements between PiCCO and FloTrac/Vigileo during hypothermia at reduced SVI (<35 ml/m2) revealed low bias and relatively narrow limits of agreement (0.5 ± 10.2 ml/m2).
Conclusion:
We found low bias, but relatively wide limits of agreement in SV with PiCCO, FloTrac/Vigileo and TTE during TTM treatment. The methods are not interchangeable. Precision was not improved by transpulmonary thermodilution calibration during hypothermia.
More Related Videos
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
10:25Normothermic Cardiac Arrest and Cardiopulmonary Resuscitation: A Mouse Model of Ischemia-Reperfusion Injury
Published on: August 30, 2011
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Therapeutic Drug Monitoring: Drug Analysis Methods
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...