Height Error Correction for Shoe-Mounted Inertial Sensors Exploiting Foot Dynamics

Estefania Munoz Diaz1, Susanna Kaiser2, Dina Bousdar Ahmed3

  • 1German Aerospace Center (DLR), Institute of Communications and Navigation, Oberpfaffenhofen, 82234 Wessling, Germany. Estefania.Munoz@dlr.de.

Summary

This study introduces a novel height correction algorithm for shoe-mounted inertial sensors, improving vertical positioning accuracy by analyzing foot dynamics on different surfaces. The method significantly reduces accumulated height errors in satellite-denied navigation.

Related Concept Videos

NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
Inertial Frames of Reference01:03

Inertial Frames of Reference

Newton’s first law is usually considered to be a statement about reference frames. It provides a method for identifying a special type of reference frame: the inertial reference frame. In principle, we can make the net force on a body zero. If its velocity relative to a given frame is constant, then that frame is said to be inertial. So, by definition, an inertial reference frame is a reference frame where Newton's first law holds valid. Newton's first law applies to objects with...
8.9K
Non-inertial Frames of Reference01:27

Non-inertial Frames of Reference

A reference frame accelerating or decelerating relative to an inertial frame is a non-inertial frame. To help understand this, consider what taking off in an airplane, turning a corner in a car, riding a merry-go-round, and the circular motion of a tropical cyclone all have in common. All these systems are accelerating, decelerating, or rotating relative to the Earth; hence, they all are non-inertial frames. All these systems exhibit inertial forces, which merely seem to arise from motion,...
7.2K
Muscles of the Leg that Move the Foot and Toes01:28

Muscles of the Leg that Move the Foot and Toes

The human leg comprises an intricate system of muscles that facilitate the movement of feet and toes. Within this system, the muscles are categorized into the anterior, lateral, and posterior compartments, each with a unique set of muscles carrying out specific functions.
Anterior Compartment
The anterior compartment includes muscles that contribute to the dorsiflexion of the foot. This compartment houses the tibialis anterior, extensor hallucis longus, and extensor digitorum longus muscles....
4.2K
Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
301
Systematic Error: Methodological and Sampling Errors01:15

Systematic Error: Methodological and Sampling Errors

In the case of systematic errors, the sources can be identified, and the errors can be subsequently minimized by addressing these sources. According to the source, systematic errors can be divided into sampling, instrumental, methodological, and personal errors.
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
11.1K