Range resolution and reproducibility of a dedicated phantom for proton PBS daily quality assurance
Lorenzo Placidi1, Michele Togno2, Damien C Weber3
1Centre for Proton Therapy, Paul Scherrer Institut, 5232 Villigen, Switzerland.
Purpose:
Wedge phantoms coupled with a CCD camera are suggested as a simple means to improve the efficiency of quality assurance for pencil beam scanning (PBS) proton therapy, in particular to verify energy/range consistency on a daily basis. The method is based on the analysis of an integral image created by a pencil beam (PB) pattern delivered through a wedge. We have investigated the reproducibility of this method and its dependence on setup and positional beam errors for a commercially available phantom (Sphinx®, IBA Dosimetry) and CCD camera (Lynx®, IBA Dosimetry) system.
Material And Methods:
The phantom includes 4 wedges of different thickness, allowing verification of the range for 4 energies within one integral image. Each wedge was irradiated with a line pattern of clinical energies (120, 150, 180 and 230MeV). The equipment was aligned to the isocenter using lasers, and the delivery was repeated for 5 consecutive days, 4 times each day. Range was computed using the myQA software (IBA Dosimetry) and inter- and intra-setup uncertainty were calculated. Dependence of range on energy was investigated delivering the same pencil beam pattern but with energy variations in steps of ±0.2MeV for all the nominal energies, up to ±1.0MeV. Possible range uncertainties, caused by setup and positional errors, were then simulated including inclination of the phantom, pencil beam and couch shifts.
Results:
Intra position setup (based on in-room laser system) shows a maximum in plane difference within 1.5mm. Range reproducibility (standard deviation) was less than 0.14mm. Setup and beam errors did not affect significantly the results, except for a vertical shift of 10mm which leads to an error in the range computation.
Conclusion:
Taking into account different day-to-day setup and beam errors, day-to-day determination of range has been shown to be reproducible using the proposed system.
Related Concept Videos
Quality Assurance
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Classical Conditioning in Daily Life
John B. Watson and Rosalie Rayner famously demonstrated the development of fear through classical conditioning in their experiment with Little Albert. They paired the...
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...