Interobserver and Intraobserver Reliability of Cone-beam Computed Tomography in Identification of Apical
Cole W Barnett1, Gerald N Glickman1, Mikhail Umorin2
1Department of Endodontics, Texas A&M University College of Dentistry, Dallas, Texas.
Introduction:
Accurate radiographic interpretation is of the utmost importance in the diagnosis and treatment of patients. Previous studies have indicated subjectivity in the radiographic interpretation of periapical tissues irrespective of using conventional radiography, digital radiography, or cone-beam computed tomographic (CBCT) imaging. No studies to date have evaluated the reliability of the interpretation of periapical tissues based on the size of periapical radiolucency (PAR). The purpose of this study was to assess the interobserver and intraobserver reliability of CBCT interpretation by observers from different specialties and different levels of experience when identifying PARs of various sizes.
Methods:
Limited field of view CBCT scans were selected such that a variety of PARs with various sizes were included. Six observers with different levels of experience and fields of specialty evaluated periradicular tissues of 28 roots on the CBCT scans at 3 separate sittings each a month apart.
Results:
The overall Fleiss kappa coefficient for interobserver reliability and intraobserver reliability was 0.88 and 0.85; the larger the PAR, the more reliable the radiographic interpretation. Increased experience level improved the intraobserver reliability.
Conclusions:
CBCT imaging appears to be a reliable method for the interpretation of PAR. The larger the PAR is the more reliable the radiographic interpretation.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Reliability and Validity
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation