Evaluation of a sequential enzyme immunoassay testing algorithm for Lyme disease demonstrates lack of test
Gary P Wormser1, Claudia R Molins2, Andrew Levin3
1Division of Infectious Diseases, New York Medical College, Valhalla, NY 10595.
Abstract:
To diagnose Lyme disease, a two-tier testing algorithm is used in which supplemental IgM and IgG immunoblots to detect antibody to Borrelia burgdorferi are reflexively performed if a first-tier assay, such as a whole-cell sonicate-based enzyme immunoassay (WCS EIA), is reactive. Recent data suggest that equal specificity is found by substituting the C6 peptide EIA for immunoblots. In this study using 3956 control sera, we demonstrated that although this two-tier testing algorithm does significantly improve diagnostic specificity compared with each of the EIAs individually, the WCS EIA and the C6 peptide EIA are not independent tests. Therefore, when the C6 peptide EIA is used as the second-tier test, it should be regarded as a supplemental rather than a confirmatory test.