Reliability of anthropometric measurements in children with special needs
Jane Hardy1, Hayley Kuter2, Malcolm Campbell3
1Department of Community Paediatrics, Manchester University NHS Foundation Trust, Manchester, UK.
Objective:
To determine the reliability of anthropometric and body composition measurements in children with special needs.
Design:
Observational study.
Setting:
Specialist support schools (primary and secondary) in Manchester, UK.
Participants:
53 children with moderate-to-severe learning disability; 30 non-standers (14 boys) and 23 standers (15 boys). Mean ages were 11 years (range 3-20) for non-standers and 12.4 years (range 8-19) for standers.
Measures:
Anthropometric measures included: height/length, segmental measures, weight, skinfolds, body circumferences and body composition estimated from bioelectrical impedance analysis (BIA). These were measured twice, 2-4 weeks apart.
Main Outcome Measures:
Reliability was assessed using the technical error of measurement (TEM).
Results:
The TEM for height and supine length was 0.55 cm for standers and 2.47 cm for non-standers, respectively. For non-standers, the TEMs for knee height and tibial length were 0.81 and 1.57 cm, respectively. The TEM for weight was 0.55 kg for standers and 0.75 kg for non-standers. For skinfold thickness, the TEM was smaller for non-standers than standers. The TEM for mid-upper arm circumference for standers and non-standers was 0.91 and 0.82 cm, respectively. The TEM for BIA in standers and non-standers was 34.7 and 54.1 Ω, respectively. Some measurements, including waist circumferences, were difficult to obtain reliably.
Conclusions:
Anthropometric and body composition measurements were feasible to obtain in children with special needs. However, the reliability of these measures differs between non-standers and standers and should be considered when choosing appropriate measures.
Related Concept Videos
Special considerations while measuring pulse
Reliability and Validity
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Special Staining Techniques
Introduction to Special Senses