Related Experiment Video
Updated: Feb 13, 2026

Evaluating the Electrochemical Properties of Supercapacitors using the Three-Electrode System
Published on: January 7, 2022
Variations in Surface Morphologies, Properties, and Electrochemical Responses to Nitro-Analyte by Controlled
Silan Bai1, Qiong Hu1, Qiang Zeng1
1School of Chemistry and Chemical Engineering , South China University of Technology , Guangzhou 510641 , People's Republic of China.
Abstract:
Herein, we reported the fabrication of conjugated microporous polymer (CMP) films based on three thiophene derivatives using a one-step templateless electropolymerization in dichloromethane without any surfactants. The formation of hydrophilic or hydrophobic films with specific morphology is a comprehensive result of the polymerization sites in each monomer, the polymerization rate, and the gas bubble produced in situ during the polymerization process, which can be easily controlled by the experimental conditions, such as electropolymerization method, electrolyte, and "trace water" existed in the organic solvent. Moreover, the electrochemical reduction of metronidazole as a prototypical nitro-analyte at CMP-modified glassy carbon (GC) electrode shows remarkably increased current response compared to nonmodified GC electrode. The process is demonstrated to be typical adsorption-controlled, and the hydrophobic surface of the electrode coating film is more favorable to the absorption and thus reduction of metronidazole. This work provides a new perspective and a breakthrough point for the application of CMPs in the electrochemical sensors.
Related Concept Videos
Variation in Acceleration due to Gravity near the Earth's Surface
The difference between the true and apparent weights is proportional to the square of the Earth's...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Response Surface Methodology
The process of RSM involves several key steps:
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Variation: Normal Distribution, Range, and Standard Deviation
Physical Properties of Carboxylic Acid Derivatives
Among the carboxylic acid derivatives, the boiling points of acid chlorides and esters are very similar and are the lowest in the series. Acid anhydrides have slightly higher boiling...