Related Experiment Video
Updated: Feb 13, 2026

Whole Body and Regional Quantification of Active Human Brown Adipose Tissue Using 18F-FDG PET/CT
Published on: April 1, 2019
Validity of Body Mass Index as a Measure of Adiposity in Infancy
Katherine A Bell1, Carol L Wagner2, Wei Perng3
1Department of Pediatric Newborn Medicine, Brigham & Women's Hospital, Boston, MA.
Insights
Body mass index (BMI) and BMI z-score (BMIZ) show moderate correlation with infant adiposity. However, BMIZ changes are poor indicators of adiposity changes later in infancy, limiting their use as surrogates.
Area of Science:
- Pediatric Nutrition
- Body Composition Analysis
- Growth Monitoring
Background:
- Accurate assessment of infant adiposity is crucial for monitoring health.
- Body Mass Index (BMI) and BMI z-score (BMIZ) are commonly used but their validity as surrogates for adiposity in infancy is not fully established.
Purpose of the Study:
- To evaluate the accuracy of BMI and BMIZ in representing infant body fat percentage (BF%), fat mass, and fat mass index at 1, 4, and 7 months.
- To determine if changes in BMIZ reflect changes in adiposity during infancy.
Main Methods:
- Secondary analysis of 447 infants from a maternal vitamin D supplementation trial.
- Dual-energy x-ray absorptiometry (DXA) used to measure body composition at 1, 4, and 7 months.
- Spearman correlations calculated between BMI/BMIZ and adiposity measures, and between changes in BMIZ and adiposity.
Main Results:
- BMIZ showed moderate correlation with BF% (rs=0.43-0.55) and stronger correlation with fat mass (rs=0.72-0.76) and fat mass index (rs=0.75-0.79) at 1, 4, and 7 months.
- Changes in BMIZ moderately correlated with adiposity changes from 1-4 months (rs=0.44-0.53) but weakly from 4-7 months (rs=0.21-0.27).
Conclusions:
- BMIZ is a moderately valid surrogate for adiposity in infancy.
- Changes in BMIZ are not reliable indicators of adiposity changes in later infancy.
- BMI and BMIZ have limitations as surrogates for tracking adiposity changes in infants.
Objectives:
To assess the validity of body mass index (BMI) and age- and sex-standardized BMI z-score (BMIZ) as surrogates for adiposity (body fat percentage [BF%], fat mass, and fat mass index [kg/m2]) at 3 time points in infancy (1, 4, and 7 months) and to assess the extent to which the change in BMIZ represents change in adiposity.
Study Design:
We performed a secondary analysis of 447 full-term infants in a previous trial of maternal vitamin D supplementation during lactation. Study staff measured infant anthropometrics and assessed body composition with dual-energy x-ray absorptiometry at 1, 4, and 7 months of age. We calculated Spearman correlations (rs) among BMI, BMIZ, and adiposity at each time point, and between change in BMIZ and change in adiposity between time points.
Results:
Infants (N = 447) were 52% male, 38% white, 31% black, and 29% Hispanic. The BMIZ was moderately correlated with BF% (rs = 0.43, 0.55, 0.48 at 1, 4, and 7 months of age, respectively). BMIZ correlated more strongly with fat mass and fat mass index, particularly at 4 and 7 months of age (fat mass rs = 0.72-0.76; fat mass index rs = 0.75-0.79). Changes in BMIZ were moderately correlated with adiposity changes from 1 to 4 months of age (rs = 0.44 with BF% change; rs = 0.53 with fat mass change), but only weakly correlated from 4 to 7 months of age (rs = 0.21 with BF% change; rs = 0.27 with fat mass change).
Conclusions:
BMIZ is moderately correlated with adiposity in infancy. Changes in BMIZ are a poor indicator of adiposity changes in later infancy. BMI and BMIZ are limited as surrogates for adiposity and especially adiposity changes in infancy.
Trial Registration:
ClinicalTrials.gov: NCT00412074.
Related Concept Videos
Socioemotional Development during Infancy
Primary Temperament Types
Reduced Mass Coordinates: Isolated Two-body Problem
Reliability and Validity
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Atomic Mass
Data Validation
Key parameters for method validation include:

