Cardioversion-Responsive Ventriculoatrial Shunt Malfunction Precipitated by Atrial Fibrillation
Wi Jin Kim1, Georgios Zenonos2, Michael M McDowell2
1Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA; University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA.
Background:
Ventriculoatrial shunts are common alternatives for patients who cannot tolerate ventriculoperitoneal shunts. The majority of ventriculoatrial shunt malfunctions are related to mechanical problems. We report an interesting case of ventriculoatrial shunt malfunction due to elevated central venous pressure from new-onset atrial fibrillation.
Methods:
After the patient was confirmed to have ventriculomegaly, he was taken to the operating room for exploration of his ventriculoatrial shunt; there were no obstructions. Subsequently, the patient was cardioverted to normal sinus rhythm for his new onset atrial fibrillation.
Results:
The clinical syndrome and ventriculomegaly both resolved after the patient's atrial fibrillation was corrected with chemical cardioversion.
Conclusions:
The cause of this patient's VA shunt malfunction was likely associated with his new onset atrial fibrillation.
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Precipitation and Co-precipitation
Precipitation Reactions