Related Experiment Video
Updated: Feb 13, 2026

Author Spotlight: Hickman Catheter Use for Long-Term Vascular Access in a Preclinical Swine Model
Published on: March 31, 2023
Cardiac implantable electronic device and vascular access: Strategies to overcome problems
Mariusz Kusztal1, Krzysztof Nowak2,3
11 Department of Nephrology and Transplantation Medicine, Wroclaw Medical University, Wroclaw, Poland.
Abstract:
For arrhythmia treatment or sudden cardiac death prevention in hemodialysis patients, there is a frequent need for placement of a cardiac implantable electronic device (pacemaker, implantable cardioverter defibrillator, or cardiac resynchronization device). Leads from a cardiac implantable electronic device can cause central vein stenosis and carry the risk of tricuspid regurgitation or contribute to infective endocarditis. In patients with end-stage kidney disease requiring vascular access and cardiac implantable electronic device, the best strategy is to create an arteriovenous fistula on the contralateral upper limb for a cardiac implantable electronic device and avoidance of central vein catheter. Fortunately, cardiac electrotherapy is moving toward miniaturization and less transvenous wires. Whenever feasible, one should avoid transvenous leads and choose alternative options such as subcutaneous implantable cardioverter defibrillator, epicardial leads, and leadless pacemaker. Based on recent reports on the leadless pacemaker/implantable cardioverter defibrillator effectiveness, in patients with rapid progression of chronic kidney disease (high risk of renal failure) or glomerular filtration rate <20 mL/min/1.73 m2, this option should be considered by the implanting cardiologist for future access protection.
Related Concept Videos
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
Seedless Vascular Plants
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Bioavailability Enhancement: Determination and Conceptual Approaches in Overcoming Bioavailability Problems
Electron Affinity
Electron Behavior
Electrons are negatively charged subatomic particles that are attracted to an orbit around the positively-charged nucleus of an atom. They reside in locations that are associated with energy levels called shells and are further organized into sub-shells and orbitals within each shell.
Electrons Orbit the Nucleus
Electrons are found in specific locations outside of the nucleus. The shell in which an electron resides indicates the general energy level of the electron: those closer to the...