Related Experiment Video
Updated: Feb 13, 2026

Quantifying Mixing using Magnetic Resonance Imaging
Published on: January 25, 2012
Cerebrospinal Fluid Pressure Reduction Results in Dynamic Changes in Optic Nerve Angle on Magnetic Resonance Imaging
Ranliang Hu1, John Holbrook, Nancy J Newman
1Department of Radiology and Imaging Sciences (RH, DQ, JO, and AMS), Emory University School of Medicine, Atlanta, Georgia; Northside Radiology Associates (JH), Atlanta, Georgia; and Department of Ophthalmology (NJN, VB, BBB), Emory University School of Medicine, Atlanta, Georgia.
Background:
Optic nerve sheath tortuosity is a previously reported, but incompletely characterized, finding in idiopathic intracranial hypertension (IIH). We hypothesized that optic nerve angle (ONA), as a quantitative measure of tortuosity, would change dynamically with cerebrospinal fluid (CSF) pressure status of patients with IIH immediately before and after lumbar puncture (LP).
Methods:
Consecutive patients with suspected IIH referred for MRI and diagnostic LP were prospectively enrolled in this single institution, institutional review board-approved study. Each patient underwent a pre-LP MRI, diagnostic LP with opening pressure (OP) and closing pressure (CP), and then post-LP MRI all within 1 session. Sagittal and axial ONAs were measured on multiplanar T2 SPACE images by 2 neuroradiologists on pre- and post-LP MRI. Effects of measured pressure and CSF volume removal on changes in ONA were analyzed as was interrater reliability for ONA measurement.
Results:
Ten patients with IIH were included {all female, median age 29 (interquartile range [IQR] 25-32)}. All patients had elevated OP (median 37, IQR 34-41 cm H2O), and significantly reduced CP (median 18, IQR 16-19 cm H2O, P < 0.001) after CSF removal (IQR 13-16 mL). Within patients, mean ONAs (sagittal and axial) were significantly lower before (162 ± 9°, 163 ± 10°) than after (168 ± 7°, 169 ± 5°) LP (P = 0.001, 0.008, respectively). Interrater reliability was higher with sagittal ONA measurements (0.89) than axial (0.72).
Conclusions:
ONA changes with short-term CSF pressure reduction in patients with IIH, establishing optic nerve tortuosity as a dynamic process related to CSF status.
Related Concept Videos
Cerebrospinal Fluid
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....
Magnetic Resonance Imaging
Pressure of Fluids
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...
Imaging Studies IV: Magnetic Resonance Imaging
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...

