The Effects of Severe Myopia on the Properties of Sampling Units in Peripheral Retina
Manbir Nagra1, Bernard Gilmartin2, Nicola S Logan2
1Centre for Applied Vision Research, City, University of London, London, United Kingdom.
Significance:
Poor peripheral visual acuity in myopia may reflect, in part, photoreceptor misalignment with the exit pupil of the eye. We speculate that if such misalignment causes sufficient visual deprivation and/or disrupts retinal feedback processes, it may influence eye growth itself.
Purpose:
It is known that myopic eyes have a reduced peripheral resolution acuity relative to emmetropic eyes, though it remains unclear how mechanical stretching of the retina in myopia impacts on peripheral visual performance. Our aim was to determine how retinal stretching affects the properties of sampling units in peripheral vision.
Methods:
Three-dimensional magnetic resonance imaging provided a depiction in vivo of ocular shape, allowing the inter-eye ratio of retinal image surface areas and the relative alignment of surfaces to be determined in our observer, who was unique in having severe myopia in the right eye (~21 D) but only modest myopia in the left (~3 D). Visual performance was assessed for the detection and direction discrimination of drifting sinusoids positioned 40° in the temporal retina. Applying the sampling theorem to our measures, we estimated the density and cut-off frequency of the underlying sampling units.
Results:
The retinal image surface area of the right eye was 40% larger than that of the left and was rotated 8.9° anticlockwise relative to the left eye's image surface. In agreement with a linear stretch model of myopia, the sampling density of the right eye was reduced by approximately the same ratio as that predicted from the inter-eye MRI data, namely, 1.18. However, the cut-off frequency (cycles/mm) of the right eye was approximately half that of the left, a reduction that cannot be explained solely by a linear areal expansion of retinal sampling units.
Conclusions:
Poor peripheral acuity in severe myopia may be caused, at least in part, by receptoral misalignment with the exit pupil.
Related Concept Videos
Measurement: Derived Units
Measurement: Standard Units
The Retina
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Units of Measurement
There are various well-known historical measurement systems, such as the Babylonian system, the Roman system, the Egyptian system, the Olympian system, the British system, and the Indus...
International System of Units
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...